Close
Frame

Isothermal Amplification

Isothermal amplification (including HAD, MCA, and LAMP) is a DNA amplification technique that has played an increasingly important role in point-of-care (POC) diagnostics. It offers several advantages over qPCR and other amplification techniques in terms of sample-to-answer time, sensitivity, specificity, cost, robustness, and accessibility, making it ideal for field-deployable diagnostics in resource-limited regions. Isothermal amplification assays have been used for numerous applications including the detection of pathogens such as salmonella and malaria, GM crop contamination, and forensics to specifically detect human DNA.
Product Filters

Clear All

Products (23)

Filters Close
Name Details Application Catalog Order a Sample Sizes Description Wet(Liquid) Air-Dryable Name Glycerol-Free Lyo-Ready Concentration High Concentration Detail Safety Data Sheet COA/Test Release User Guide Product Handling Guide Product Manual
Glycerol-Free Phi29 DNA Polymerase (HC) DNA WGA MDX240 Order a Sample Available in 20 µL (2,000 Unit) or 100 µL (10,000 Unit) aliquots

Glycerol-free, high concentration enzyme with exceptional strand displacement and processive synthesis properties, ideal for rolling-circle amplification (RCA).

Liquid Requires excipients Requires excipients Yes Requires excipients 100 U/?L Yes
Glycerol-Free Thermostable DNA Helicase (HC) DNA tHAD MDX242 Order a Sample Available in 20 ?L (1 µg) or 200 ?L (10 µg) aliquots

Glycerol-free, high concentration enzyme used with in isothermal amplification method such as LAMP, RPA, RCA, SDA and tHDA)

Liquid Requires excipients Requires excipients Yes Requires excipients 50 µg/mL Yes
Bst DNA Polymerase DNA LAMP MDX012 Order a Sample Available in 1 mL or 10 mL aliquots

DNA polymerase (exo-), with strand-displacement properties. used for Isothermal DNA amplification such as LAMP (Loop-mediated Isothermal Amplification).

Liquid No No No No 8 units/mL No
High Conc. Glycerol-Free Bst DNA LAMP MDX018 Order a Sample Available in 80 µL or 800 µL aliquots

High concentration glycerol-free DNA polymerase (exo-), with strand-displacement properties. used for Isothermal DNA amplification such as LAMP (Loop-mediated Isothermal Amplification).

Liquid Yes Requires excipients Yes Yes 100 units/mL Yes
Inhibitor-Tolerant Bst Buffer DNA LAMP MDX019 Order a Sample Available in 2 mL or 100 mL aliquots

Inhibitor-Tolerant Bst Buffer is specially designed to overcome the inhibition present in samples in direct LAMP reactions.

Liquid Yes Requires excipients Yes Yes 10x No
Bst Reaction Buffer, 10x DNA LAMP MDX076 Order a Sample Available in 5 mL or 100 mL aliquots

Reaction Buffer optimized for use with Bst DNA Polymerase.

Liquid Requires excipients Requires excipients Yes Requires excipients 10x No
Enzyme Dilution Buffer, 1x DNA PCR MDX078 Order a Sample Available in 5 mL or 100 mL aliquots

Glycerol containing1x dilution buffer, for the dilution of enzymes to reaction concentration.

Liquid No No No No 1x No
Enzyme Dilution Buffer, 10x (Glycerol free) DNA PCR MDX080 Order a Sample Available in 5 mL or 100 mL aliquots

Glycerol-free,10x dilution buffer, for the dilution of enzymes to reaction concentration.

Liquid Yes Air-Dryable,Lyo-Ready Yes Yes 10x No
Lyo-Ready LAMP Mix, 4x DNA LAMP MDX097 Order a Sample Available in 5 mL (800 Rxns) or 50 mL (8,000 Rxns) aliquots

Glycerol-free mix for isothermal applications such as LAMP, containing Bst DNA polymerase, reaction buffer, dNTPs and lyo-compatible excipients, ideal for developing ambient temperature, LAMP assays.

Liquid No Lyo-Ready Yes Yes 4x Yes
Lyo-Ready RT-LAMP 1-Step Mix, 4x RNA RT-LAMP MDX108 Order a Sample Available in 5 mL (800 Rxns) or 50 mL (8,000 Rxns) aliquots

Glycerol-free mix for isothermal applications such as RT-LAMP, containing Bst DNA polymerase, reverse transcriptase, reaction buffer, dNTPs and lyo-compatible excipients, ideal for developing ambient temperature, LAMP assays.

Liquid No Lyo-Ready Yes Yes 4x Yes
Air-Dryable RT-LAMP 1-Step Mix, 4x RNA RT-LAMP MDX118 Order a Sample Available in 5 mL (800 Rxns) or 50 mL (8,000 Rxns) aliquots

Glycerol-free mix for isothermal applications such as RT-LAMP, containing Bst DNA polymerase, reverse transcriptase, reaction buffer, dNTPs and air-dryable excipients, ideal for developing ambient temperature, LAMP assays.

Liquid Yes Air-Dryable Yes No 4x Yes
Air-Dryable DNA LAMP DNA LAMP MDX119 Order a Sample Available in 5 mL (800 Rxns) or 50 mL (8,000 Rxns) aliquots

Glycerol-free mix for isothermal applications such as LAMP, containing Bst DNA polymerase, reaction buffer, dNTPs and air-dryable excipients, ideal for developing ambient temperature, LAMP assays.

Liquid Yes Air-Dryable Yes No 4x Yes
Lyo-Ready Direct DNA LAMP Blood, 4x Blood, Plasma, Serum, DNA LAMP MDX124 Order a Sample Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots

Inhibitor tolerance to 20% whole blood, 20% plasma, compatible with all anticoagulants. Perfect for multiplexing and fast cycling conditions. Used in the detection of blood pathogens and liquid biopsy applications.

Liquid No Lyo-Ready Yes Yes 4x Yes
Lyo-Ready Direct RNA/DNA LAMP Blood, 4x Blood, Plasma, Serum, RNA RT-LAMP MDX125 Order a Sample Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots

Inhibitor tolerance to 10% whole blood, 10% plasma, compatible with all anticoagulants. Perfect for multiplexing and fast cycling conditions. Used in the detection of blood pathogens and liquid biopsy applications.

Liquid No Lyo-Ready Yes Yes 4x Yes
Lyo-Ready Direct DNA LAMP Saliva, 4x Saliva, Sputum, DNA LAMP MDX134 Order a Sample Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots

Inhibitor tolerance to 60% crude saliva, sputum or mucin samples and 50% UTM. Perfect for multiplexing and fast cycling conditions. Used in the detection of a broad range of diseases, including cancer, respiratory viruses and bacterial infections.

Liquid No Lyo-Ready Yes Yes 4x Yes
Lyo-Ready Direct RNA/DNA LAMP Saliva, 4x Saliva, Sputum, RNA RT-LAMP MDX135 Order a Sample Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots

Inhibitor tolerance to 60% crude saliva, sputum or mucin samples and 50% UTM. Perfect for multiplexing and fast cycling conditions. Used in the detection of a broad range of diseases, including cancer, respiratory viruses and bacterial infections.

Liquid No Lyo-Ready Yes Yes 4x Yes
Lyo-Ready Direct DNA LAMP Stool, 4x Stool, DNA LAMP MDX144 Order a Sample Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots

Inhibitor tolerance to 20% stool, 2 mg/mL bile salt and 40% Cary Blair media. Perfect for multiplexing and fast cycling conditions. Used in the detection of IBD, cancer, fecal microbiota and bacterial and viruses.

Liquid No Lyo-Ready Yes Yes 4x Yes
Lyo-Ready Direct RNA/DNA LAMP Stool, 4x Stool, RNA RT-LAMP MDX145 Order a Sample Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots

Inhibitor tolerance to 5% stool, 2 mg/mL bile salt and 40% Cary Blair media. Perfect for multiplexing and fast cycling conditions. Used in the detection of IBD, cancer, fecal microbiota and bacterial and viruses.

Liquid No Lyo-Ready Yes Yes 4x Yes
Air-Dryable Direct DNA LAMP Blood, 4x Blood, Plasma, Serum, DNA LAMP MDX126 Order a Sample Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots

Inhibitor tolerance to 10% whole blood, 10% plasma, compatible with all anticoagulants. Perfect for multiplexing and fast cycling conditions. Used in the detection of blood pathogens and liquid biopsy applications.

Liquid Yes Air-Dryable Yes No 4x Yes
Lyo-Ready Direct DNA LAMP Urine, 4x Urine, DNA LAMP MDX154 Order a Sample Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots

Inhibitor tolerance to 20% urine. Perfect for multiplexing and fast cycling conditions. Used in the detection of urinary track infections, STD, tropical diseases, cancer screening, bladder and prostate cancer.

Liquid No Lyo-Ready Yes Yes 4x Yes
Lyo-Ready Direct RNA/DNA LAMP Urine, 4x Urine, RNA RT-LAMP MDX155 Order a Sample Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots

Inhibitor tolerance to 20% urine. Perfect for multiplexing and fast cycling conditions. Used in the detection of urinary track infections, STD, tropical diseases, cancer screening, bladder and prostate cancer.

Liquid No Lyo-Ready Yes Yes 4x Yes
Glycerol-Free T7 RNA Polymerase (HC) RNA NASBA MDX201 Order a Sample Available in 50,000 Unit or 500,000 Unit aliquots

Glycerol-free, high concentration DNA-dependant RNA Polymerase that requires a T7 promoter sequence, it an ideal enzyme for in-vitro synthesis of labeled or unlabeled RNA for research, diagnostic or clinical applications. Ideal for lyophilization.

Liquid Requires excipients Requires excipients Yes Requires excipients 1,000 U/µL Yes
Glycerol-Free RNase H (HC) RNA RT-qPCR MDX202 Order a Sample Available in 100 µL (2,500 Unit) or 250 µL (12,500 Unit) aliquots

Glycerol-free, high concentration RNA-specific endonuclease that hydrolyzes the phosphodiester bonds of RNA, when hybridized to DNA. Ideal for lyophilization.

Liquid Requires excipients Requires excipients Yes Requires excipients 50 U/µL Yes

Not seeing what you’re looking for? Inquire about a new product

Sample Specific Inhibitor Tolerant LAMP Mixes

Loop mediated isothermal amplification LAMP, for example, uses four to six primers that recognize several specific regions in the target DNA. The reaction is initiated by a strand-displacement polymerase such as Bst DNA polymerase and two specially designed primers which form loop structures to facilitate subsequent rounds of amplification producing high levels of DNA. LAMP reactions are very robust and inhibitor-tolerant, producing extremely large amounts of DNA that can be visualized by the eye (e.g. as a precipitate or color change). Specifically, 1 to 10 copies of DNA can be amplified to 109 to 1010 copies within 30 minutes, producing assays with excellent sensitivity and specificity.

For even greater tolerance, Meridian has also developed sample specific inhibitor tolerant LAMP mixes, designed to be used for direct amplification from crude lysates or inhibitor-rich samples, with the ability to tolerate even higher levels of inhibitors present in samples. In addition these mixes can be used as wet mixes or dried by lyophilization or air-drying for room temperature shipping and storage, extended shelf-life, and increased flexibility in sample volume, making them ideal for POCT development where minimal sample processing and fast turn-around times are essential.

Advanced Isothermal Amplification Solutions

Why We Are Second To None

Meridian offers diagnostic manufacturers the complete solution with over 3,000 antigens and antibodies covering more than 500 diseases and an extensive range of specialty qPCR/RT-qPCR master mixes and molecular enzymes all manufactured under ISO13485 regulations.

  • Path Copy

    Large Sample Size

  • Lot Reservation

    Lot Reservation

  • ISO13485

    ISO13485

  • World-Class Customer Service

    World-Class Customer Service

Get In Touch With A Specialist

Have questions about a product? Want to learn more about Meridian’s molecular or immunoassay reagent portfolio? We want to hear from you!


By submitting your information in this form, you agree that your personal information may be stored and processed in any country where we have facilities or service providers, and by using our “Contact Us” page you agree to the transfer of information to countries outside of your country of residence, including to the United States, which may provide for different data protection rules than in your country. The information you submit will be governed by our Privacy Statement.
Learn More About Us
About
Welcome to
logo blue

Please select your country to continue

Continue
CN