Ready to Use Master Mixes
Product Filters
Products (69)
Name | Details | Application | Catalog | Order a Sample | Sizes | Description | Wet(Liquid) | Air-Dryable | Name | Glycerol-Free | Lyo-Ready | Concentration | High Concentration | Detail | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | Product Manual | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air-Dryable Direct DNA LAMP Blood, 4x | Blood, Plasma, Serum, LAMP Mixes | RT-LAMP | MDX126 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | Inhibitor tolerance to 10% whole blood, 10% plasma, compatible with all anticoagulants. Perfect for multiplexing and fast cycling conditions. Used in the detection of blood pathogens and liquid biopsy applications. |
Yes | Yes | Air-Dryable | Yes | No | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Lyo-Ready Direct RNA/DNA LAMP Urine, 4x | Urine, LAMP Mixes | RT-LAMP | MDX155 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | Inhibitor tolerance to 20% urine. Perfect for multiplexing and fast cycling conditions. Used in the detection of urinary track infections, STD, tropical diseases, cancer screening, bladder and prostate cancer. |
Yes | No | Lyo-Ready | Yes | Yes | 4x | Yes | View Details | COA/Test Release | User Guide | Product Handling Guide | ||||
Lyo-Ready Genotyping Direct qPCR Urine, 4x | Urine, Lyo-Ready Mix | SNP Genotyping | MDX158 | Order a Sample | Available in 1,000 Unit or 10,000 Unit aliquots | Inhibitor tolerance to 20% urine. Compatible with all dual-label probe chemistries for detection of genetic variants, such as single nucleotide and copy number variants, to give highly reproducible allelic discrimination. |
Yes | No | Lyo-Ready | Yes | Yes | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Lyo-Ready Genotyping Direct qPCR FFPE, 4x | FFPE, Lyo-Ready Mix | SNP Genotyping | MDX168 | Order a Sample | Available in 1,000 Unit or 10,000 Unit aliquots | Better extraction buffers and greater tolerance to crude FFPE samples. Compatible with all dual-label probe chemistries for detection of genetic variants, such as single nucleotide and copy number variants, to give highly reproducible allelic discrimination. |
Yes | No | Lyo-Ready | Yes | Yes | 4x | Yes | View Details | COA/Test Release | User Guide | Product Handling Guide | ||||
Glycerol-Free T7 RNA Polymerase (HC) | NASBA | NASBA | MDX201 | Order a Sample | Available in 50,000 Unit or 500,000 Unit aliquots | Glycerol-free, high concentration DNA-dependant RNA Polymerase that requires a T7 promoter sequence, it an ideal enzyme for in-vitro synthesis of labeled or unlabeled RNA for research, diagnostic or clinical applications. Ideal for lyophilization. |
Yes | Requires excipients | Requires excipients | Yes | Requires excipients | 1,000 U/µL | Yes | View Details | COA/Test Release | Product Handling Guide | |||||
Glycerol-Free RNase H (HC) | Reverse Transcriptase, NGS Enzymes, NASBA | RT-qPCR | MDX202 | Order a Sample | Available in 100 µL (2,500 Unit) or 250 µL (12,500 Unit) aliquots | Glycerol-free, high concentration RNA-specific endonuclease that hydrolyzes the phosphodiester bonds of RNA, when hybridized to DNA. Ideal for lyophilization. |
Yes | Requires excipients | Requires excipients | Yes | Requires excipients | 50 U/µL | Yes | View Details | COA/Test Release | Product Handling Guide | |||||
Lyo-Ready Direct RNA/DNA LAMP Blood, 4x | Blood, Plasma, Serum, LAMP Mixes | RT-LAMP | MDX125 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | Inhibitor tolerance to 10% whole blood, 10% plasma, compatible with all anticoagulants. Perfect for multiplexing and fast cycling conditions. Used in the detection of blood pathogens and liquid biopsy applications. |
Yes | No | Lyo-Ready | Yes | Yes | 4x | Yes | View Details | COA/Test Release | User Guide | Product Handling Guide | ||||
Lyo-Ready Genotyping Direct qPCR Blood, 4x | Blood, Plasma, Serum, Lyo-Ready Mix | SNP Genotyping | MDX128 | Order a Sample | Available in 1,000 Unit or 10,000 Unit aliquots | Inhibitor tolerance to 10% whole blood, 20% plasma. Compatible with all dual-label probe chemistries for detection of genetic variants, such as single nucleotide and copy number variants, to give highly reproducible allelic discrimination. |
Yes | No | Lyo-Ready | Yes | Yes | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Air-Dryable Direct DNA qPCR Saliva, 4x | Saliva, Sputum, Air-Dryable Mix | qPCR | MDX130 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | Inhibitor tolerance to 60% crude saliva, sputum or mucin samples and 50% UTM. Perfect for multiplexing and fast cycling conditions. Used in the detection of a broad range of diseases, including cancer, respiratory viruses and bacterial infections. |
Yes | Yes | Air-Dryable | Yes | No | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Air-Dryable Direct RNA/DNA qPCR Saliva, 4x | Saliva, Sputum, Air-Dryable Mix | RT-qPCR | MDX131 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | Inhibitor tolerance to 60% crude saliva, sputum or mucin samples and 50% UTM. Perfect for multiplexing and fast cycling conditions. Used in the detection of a broad range of diseases, including cancer, respiratory viruses and bacterial infections. |
Yes | Yes | Air-Dryable | Yes | No | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Lyo-Ready Direct DNA qPCR Saliva, 4x | Saliva, Sputum, Lyo-Ready Mix | qPCR | MDX132 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | Inhibitor tolerance to 60% crude saliva, sputum or mucin samples and 50% UTM. Perfect for multiplexing and fast cycling conditions. Used in the detection of a broad range of diseases, including cancer, respiratory viruses and bacterial infections. |
Yes | No | Lyo-Ready | Yes | Yes | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Lyo-Ready Direct RNA/DNA qPCR Saliva, 4x | Saliva, Sputum, Lyo-Ready Mix | RT-qPCR | MDX133 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | Inhibitor tolerance to 60% crude saliva, sputum or mucin samples and 50% UTM. Perfect for multiplexing and fast cycling conditions. Used in the detection of a broad range of diseases, including cancer, respiratory viruses and bacterial infections. |
Yes | No | Lyo-Ready | Yes | Yes | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Lyo-Ready Direct DNA LAMP Saliva, 4x | Saliva, Sputum, LAMP Mixes | LAMP | MDX134 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | Inhibitor tolerance to 60% crude saliva, sputum or mucin samples and 50% UTM. Perfect for multiplexing and fast cycling conditions. Used in the detection of a broad range of diseases, including cancer, respiratory viruses and bacterial infections. |
Yes | No | Lyo-Ready | Yes | Yes | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Lyo-Ready Direct RNA/DNA LAMP Saliva, 4x | Saliva, Sputum, LAMP Mixes | RT-LAMP | MDX135 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | Inhibitor tolerance to 60% crude saliva, sputum or mucin samples and 50% UTM. Perfect for multiplexing and fast cycling conditions. Used in the detection of a broad range of diseases, including cancer, respiratory viruses and bacterial infections. |
Yes | No | Lyo-Ready | Yes | Yes | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Air-Dryable Direct DNA qPCR Stool, 4x | Stool, Air-Dryable Mix | qPCR | MDX140 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | Inhibitor tolerance to 20% stool, 2 mg/mL bile salt and 40% Cary Blair media. Perfect for multiplexing and fast cycling conditions. Used in the detection of IBD, cancer, fecal microbiota and bacterial and viruses. |
Yes | Yes | Air-Dryable | Yes | No | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Air-Dryable Direct RNA/DNA qPCR Stool, 4x | Stool, Air-Dryable Mix | RT-qPCR | MDX141 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | Inhibitor tolerance to 5% stool, 2 mg/mL bile salt and 40% Cary Blair media. Perfect for multiplexing and fast cycling conditions. Used in the detection of IBD, cancer, fecal microbiota and bacterial and viruses. |
Yes | Yes | Air-Dryable | Yes | No | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Lyo-Ready Direct DNA qPCR Stool, 4x | Stool, Lyo-Ready Mix | qPCR | MDX142 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | Inhibitor tolerance to 20% stool, 2 mg/mL bile salt and 40% Cary Blair media. Perfect for multiplexing and fast cycling conditions. Used in the detection of IBD, cancer, fecal microbiota and bacterial and viruses. |
Yes | No | Lyo-Ready | Yes | Yes | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Lyo-Ready Direct RNA/DNA qPCR Stool, 4x | Stool, Lyo-Ready Mix | RT-qPCR | MDX143 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | Inhibitor tolerance to 5% stool, 2 mg/mL bile salt and 40% Cary Blair media. Perfect for multiplexing and fast cycling conditions. Used in the detection of IBD, cancer, fecal microbiota and bacterial and viruses. |
Yes | No | Lyo-Ready | Yes | Yes | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Lyo-Ready Direct DNA LAMP Stool, 4x | Stool, LAMP Mixes | LAMP | MDX144 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | Inhibitor tolerance to 20% stool, 2 mg/mL bile salt and 40% Cary Blair media. Perfect for multiplexing and fast cycling conditions. Used in the detection of IBD, cancer, fecal microbiota and bacterial and viruses. |
Yes | No | Lyo-Ready | Yes | Yes | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Lyo-Ready Direct RNA/DNA LAMP Stool, 4x | Stool, LAMP Mixes | RT-LAMP | MDX145 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | Inhibitor tolerance to 5% stool, 2 mg/mL bile salt and 40% Cary Blair media. Perfect for multiplexing and fast cycling conditions. Used in the detection of IBD, cancer, fecal microbiota and bacterial and viruses. |
Yes | No | Lyo-Ready | Yes | Yes | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Lyo-Ready Genotyping Direct qPCR Stool, 4x | Stool, Lyo-Ready Mix | SNP Genotyping | MDX148 | Order a Sample | Available in 1,000 Unit or 10,000 Unit aliquots | Inhibitor tolerance to 20% stool. Compatible with all dual-label probe chemistries for detection of genetic variants, such as single nucleotide and copy number variants, to give highly reproducible allelic discrimination. |
Yes | No | Lyo-Ready | Yes | Yes | 4x | Yes | View Details | COA/Test Release | Product Handling Guide | |||||
Air-Dryable Direct DNA qPCR Urine, 4x | Urine, Air-Dryable Mix | qPCR | MDX150 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | Inhibitor tolerance to 60% urine. Perfect for multiplexing and fast cycling conditions. Used in the detection of urinary track infections, STD, tropical diseases, cancer screening, bladder and prostate cancer. |
Yes | Yes | Air-Dryable | Yes | No | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Air-Dryable Direct RNA/DNA qPCR Urine, 4x | Urine, Air-Dryable Mix | RT-qPCR | MDX151 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | Inhibitor tolerance to 20% urine. Perfect for multiplexing and fast cycling conditions. Used in the detection of urinary track infections, STD, tropical diseases, cancer screening, bladder and prostate cancer. |
Yes | Yes | Air-Dryable | Yes | No | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Lyo-Ready Direct DNA qPCR Urine, 4x | Urine, Lyo-Ready Mix | qPCR | MDX152 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | Inhibitor tolerance to 20% urine. Perfect for multiplexing and fast cycling conditions. Used in the detection of urinary track infections, STD, tropical diseases, cancer screening, bladder and prostate cancer. |
Yes | No | Lyo-Ready | Yes | Yes | 4x | Yes | View Details | COA/Test Release | User Guide | Product Handling Guide | ||||
Lyo-Ready Direct RNA/DNA qPCR Urine, 4x | Urine, Lyo-Ready Mix | RT-qPCR | MDX153 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | Inhibitor tolerance to 20% urine. Perfect for multiplexing and fast cycling conditions. Used in the detection of urinary track infections, STD, tropical diseases, cancer screening, bladder and prostate cancer. |
Yes | No | Lyo-Ready | Yes | Yes | 4x | Yes | View Details | COA/Test Release | User Guide | Product Handling Guide | ||||
Lyo-Ready Direct DNA LAMP Urine, 4x | Urine, LAMP Mixes | LAMP | MDX154 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | Inhibitor tolerance to 20% urine. Perfect for multiplexing and fast cycling conditions. Used in the detection of urinary track infections, STD, tropical diseases, cancer screening, bladder and prostate cancer. |
Yes | No | Lyo-Ready | Yes | Yes | 4x | Yes | View Details | COA/Test Release | User Guide | Product Handling Guide | ||||
Air-Dryable qPCR Mix, 4x | PCR, qPCR, Air-Dryable Mix | qPCR | MDX082 | Order a Sample | Available in 5 mL (500 Rxns) or 50 mL (10,000 Rxns) aliquots | Glycerol-free qPCR mix containing Taq polymerase, reaction buffer, dNTPs, MgCl2 and air-dry compatible excipients, ideal for developing ambient temperature, multiplex molecular assays. |
Yes | Yes | Air-Dryable | Yes | No | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | ||||
Air-Dryable Direct DNA qPCR Blood, 4x | Blood, Plasma, Serum, Air-Dryable Mix | qPCR | MDX092 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | Inhibitor tolerance to 20% whole blood, 20% plasma, compatible with all anticoagulants. Perfect for multiplexing and fast cycling conditions. Used in the detection of blood pathogens and liquid biopsy applications. |
Yes | Yes | Air-Dryable | Yes | No | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Air-Dryable 1-Step RT-qPCR Mix, 4x | Air-Dryable Mix | RT-qPCR | MDX095 | Order a Sample | Available in 5 mL (500 Rxns) or 50 mL (10,000 Rxns) aliquots | Glycerol-free RT-qPCR mix containing Taq polymerase, reverse transcriptase, reaction buffer, dNTPs, MgCl2 and air-dry compatible excipients, ideal for developing ambient temperature, multiplex molecular assays. |
Yes | Yes | Air-Dryable | Yes | No | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Lyo-Ready LAMP Mix, 4x | LAMP Mixes | LAMP | MDX097 | Order a Sample | Available in 5 mL (800 Rxns) or 50 mL (8,000 Rxns) aliquots | Glycerol-free mix for isothermal applications such as LAMP, containing Bst DNA polymerase, reaction buffer, dNTPs and lyo-compatible excipients, ideal for developing ambient temperature, LAMP assays. |
Yes | No | Lyo-Ready | Yes | Yes | 4x | Yes | View Details | COA/Test Release | User Guide | Product Handling Guide | ||||
Inhibitor-Tolerant RT-qPCR Lo-ROX Mix, 4x | Blood, saliva, urine, stool, tissue | RT-qPCR | MDX105 | Order a Sample | Available in 5 mL (500 Rxns) or 50 mL (10,000 Rxns) aliquots | Combination of the latest advances in buffer chemistry and PCR enhancers and stabilizers, together with high quality enzymes, dNTPs and MgCl2, for use in the presence of inhibitors. |
Yes | No | No | No | No | 4x | Yes | View Details | COA/Test Release | Product Handling Guide | |||||
Lyo-Ready RT-LAMP 1-Step Mix, 4x | LAMP Mixes | RT-LAMP | MDX108 | Order a Sample | Available in 5 mL (800 Rxns) or 50 mL (8,000 Rxns) aliquots | Glycerol-free mix for isothermal applications such as RT-LAMP, containing Bst DNA polymerase, reverse transcriptase, reaction buffer, dNTPs and lyo-compatible excipients, ideal for developing ambient temperature, LAMP assays. |
Yes | No | Lyo-Ready | Yes | Yes | 4x | Yes | View Details | COA/Test Release | User Guide | Product Handling Guide | ||||
Lyo-Ready dUTP 1-Step RT-qPCR Mix | Lyo-Ready Mix, Lyo-Ready Mix | RT-qPCR | MDX113 | Order a Sample | Available in 10 mL (1,000 Rxns) or 100 mL (10,000 Rxns) aliquots | Glycerol-free mix containing Taq polymerase, RNase Inhibitor, reaction buffer, dNTP/dUTP mix, MgCl2 and lyo-excipients and separate reverse transcriptase , developed to remove background PCR product contamination. |
Yes | No | Lyo-Ready | Yes | Yes | 2x | No | View Details | COA/Test Release | Product Handling Guide | |||||
Air-Dryable Direct DNA qPCR Plant, 4x | Plant, Air-Dryable Mix | qPCR | MDX116 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | No need for extraction, compatible with 25% Plant lysate (SDS, NaOH). Perfect for multiplexing and fast cycling conditions for in-field qPCR testing. Used for genotyping and transgene or pathogenic detection. |
Yes | Yes | Air-Dryable | Yes | No | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
55C MMLV-RT | Reverse Transcriptase, Air-Dryable & Lyo-Ready Enzymes | RT-LAMP | MDX117 | Order a Sample | Available in 50 µL (10,000 Units), 200 µL (40,000 Units) or 1 mL (200,000 Units) aliquot | Highly robust, thermostable reverse transcriptase, ideal for cDNA synthesis from RNA with a high secondary structure such as viral RNA genomes. |
Yes | Requires excipients | Requires excipients | Yes | Requires excipients | 200 U/µL | Yes | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Air-Dryable RT-LAMP 1-Step Mix, 4x | LAMP Mixes | RT-LAMP | MDX118 | Order a Sample | Available in 5 mL (800 Rxns) or 50 mL (8,000 Rxns) aliquots | Glycerol-free mix for isothermal applications such as RT-LAMP, containing Bst DNA polymerase, reverse transcriptase, reaction buffer, dNTPs and air-dryable excipients, ideal for developing ambient temperature, LAMP assays. |
Yes | Yes | Air-Dryable | Yes | No | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Air-Dryable DNA LAMP | LAMP Mixes | LAMP | MDX119 | Order a Sample | Available in 5 mL (800 Rxns) or 50 mL (8,000 Rxns) aliquots | Glycerol-free mix for isothermal applications such as LAMP, containing Bst DNA polymerase, reaction buffer, dNTPs and air-dryable excipients, ideal for developing ambient temperature, LAMP assays. |
Yes | Yes | Air-Dryable | Yes | No | 4x | Yes | View Details | COA/Test Release | User Guide | Product Handling Guide | ||||
Air-Dryable Direct RNA/DNA qPCR Blood, 4x | Blood, Plasma, Serum, Air-Dryable Mix | RT-qPCR | MDX121 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | Inhibitor tolerance to 10% whole blood, 10% plasma, compatible with all anticoagulants. Perfect for multiplexing and fast cycling conditions. Used in the detection of blood pathogens and liquid biopsy applications. |
Yes | Yes | Air-Dryable | Yes | No | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Lyo-Ready Direct DNA qPCR Blood, 4x | Blood, Plasma, Serum, Lyo-Ready Mix | qPCR | MDX122 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | Inhibitor tolerance to 20% whole blood, 20% plasma, compatible with all anticoagulants. Perfect for multiplexing and fast cycling conditions. Used in the detection of blood pathogens and liquid biopsy applications. |
Yes | No | Lyo-Ready | Yes | Yes | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Lyo-Ready Direct RNA/DNA qPCR Blood, 4x | Blood, Plasma, Serum, Lyo-Ready Mix | RT-qPCR | MDX123 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | Inhibitor tolerance to 10% whole blood, 10% plasma, compatible with all anticoagulants. Perfect for multiplexing and fast cycling conditions. Used in the detection of blood pathogens and liquid biopsy applications. |
Yes | No | Lyo-Ready | Yes | Yes | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Lyo-Ready Direct DNA LAMP Blood, 4x | Blood, Plasma, Serum, LAMP Mixes | LAMP | MDX124 | Order a Sample | Available in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquots | Inhibitor tolerance to 20% whole blood, 20% plasma, compatible with all anticoagulants. Perfect for multiplexing and fast cycling conditions. Used in the detection of blood pathogens and liquid biopsy applications. |
Yes | No | Lyo-Ready | Yes | Yes | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Lyo-Ready 1-Step RT-qPCR Buffer | Buffer, Air-Dryable & Lyo-Ready Enzymes | RT-qPCR | MDX052 | Order a Sample | Available in 10 mL (1,000 Rxns) or 100 mL (10,000 Rxns) aliquots | Glycerol-free RT-qPCR reaction buffer containing lyo-excipients, designed to deliver highly reproducible, accurate RT-qPCR assay results under fast thermal cycling conditions. |
Yes | No | Lyo-Ready | Yes | Yes | 2x | No | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Hi-throughput dUTP qPCR Lo-ROX | PCR, qPCR, dU Containing | qPCR | MDX060 | Order a Sample | Available in 10 mL (1,000 Rxns) or 100 mL (10,000 Rxns) aliquots | Contains Taq polymerase, reaction buffer, dNTP, MgCl2, stabilizers, PCR enhancers, and ROX dye. The dTTP has been substituted for dUTP, so that UDGase can be added to remove background PCR carryover product contamination. |
Yes | No | No | No | No | 2x | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Lyo-Ready qPCR Buffer w/o Excipients, 4x | Buffer, Air-Dryable & Lyo-Ready Enzymes | qPCR | MDX061 | Order a Sample | Available in 2.5 mL (500 Rxns) or 100 mL (20,000 Rxns) aliquots | Glycerol-free qPCR reaction buffer that is designed to allow formulation optimization to freeze-drying methods by excipients selection. |
Yes | Requires excipients | Air-Dryable,Lyo-Ready | Yes | Requires excipients | 4x | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Lyo-Ready 1-Step RT-qPCR Virus Mix | Lyo-Ready Mix, Lyo-Ready Mix | RT-qPCR | MDX062 | Order a Sample | Available in 10 mL (1,000 Rxns) or 100 mL (10,000 Rxns) aliquots | Taq polymerase, RNase inhibitor, reaction buffer, dNTP, MgCl2 and lyo-excipients and separate reverse transcriptase, optimized for amplification of RNA with high secondary structure. |
Yes | No | Lyo-Ready | Yes | Yes | 2x | No | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Fast qPCR Mix, 5x | PCR, qPCR | qPCR | MDX072 | Order a Sample | Available in 2 mL (500 Rxns) or 40 mL (10,000 Rxns) aliquots | The latest advances in buffer chemistry and PCR enhancers and stabilizers, together with a hot-start polymerase, dNTPs and MgCl2, for highly reproducible, accurate assay results under fast thermal cycling conditions. |
Yes | No | No | No | No | 5x | Yes | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Inhibitor-Tolerant qPCR Mix, 5x | PCR, qPCR | qPCR | MDX073 | Order a Sample | Available in 2 mL (500 Rxns) or 40 mL (10,000 Rxns) aliquots | Combination of the latest advances in buffer chemistry and PCR enhancers and stabilizers, together with high quality enzymes, dNTPs and MgCl2, for use in the presence of inhibitors. |
Yes | No | No | No | No | 5x | Yes | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Bst Reaction Buffer, 10x | Buffer, Bst Enzymes & Buffers | LAMP | MDX076 | Order a Sample | Available in 5 mL or 100 mL aliquots | Reaction Buffer optimized for use with Bst DNA Polymerase. |
Yes | Requires excipients | Requires excipients | Yes | Requires excipients | 10x | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Enzyme Dilution Buffer, 1x | Buffer, Bst Enzymes & Buffers | PCR | MDX078 | Order a Sample | Available in 5 mL or 100 mL aliquots | Glycerol containing1x dilution buffer, for the dilution of enzymes to reaction concentration. |
Yes | No | No | No | No | 1x | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Enzyme Dilution Buffer, 10x (Glycerol free) | Buffer, Bst Enzymes & Buffers | PCR | MDX080 | Order a Sample | Available in 5 mL or 100 mL aliquots | Glycerol-free,10x dilution buffer, for the dilution of enzymes to reaction concentration. |
Yes | Yes | Air-Dryable,Lyo-Ready | Yes | Yes | 10x | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Lyo-Ready 1-Step RT-qPCR Mix | Lyo-Ready Mix | RT-qPCR | MDX024 | Order a Sample | Available in 10 mL (1,000 Rxns) or 100 mL (10,000 Rxns) aliquots | Glycerol-free Taq polymerase, reaction buffer, dNTP, MgCl2, and lyo-excipients, and separate thermostable reverse transcriptase, ideal for developing room temperature, lyophilized, multiplex qPCR assays. |
Yes | No | Lyo-Ready | Yes | Yes | 2x | No | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Low LOD 1-Step RT-qPCR Mix | RT-PCR, RT-qPCR | RT-qPCR | MDX025 | Order a Sample | Available in 10 mL (1,000 Rxns) or 100 mL (10,000 Rxns) aliquots. | RT-qPCR mix a dNTP/dUTP mix, designed for stringent amplification of highly structured and very low copy-number RNA and DNA targets. |
Yes | No | No | No | No | 2x | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Low DNA qPCR Mix | PCR, qPCR | qPCR | MDX030 | Order a Sample | Available in 5 mL (500 Rxns) or 100 mL (10,000 Rxns) aliquots | Highly purified qPCR master mix with stringent chemical hot-start properties and low bioburden, ideal for PCR of low-copy bacterial targets to avoid false-positive amplification. |
Yes | No | No | No | No | 2x | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Hi-throughput dUTP qPCR Mix | PCR, qPCR, dU Containing | qPCR | MDX031 | Order a Sample | Available in 5 mL (500 Rxns) or 100 mL (10,000 Rxns) aliquots | qPCR mix containing Taq polymerase, reaction buffer, dNTP/dUTP mix and MgCl2, developed to remove background PCR product contamination. |
Yes | No | No | No | No | 2x | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Fast 1-Step RT-qPCR Mix | RT-PCR, RT-qPCR | RT-qPCR | MDX032 | Order a Sample | Available in 5 mL (500 Rxns) or 100 mL (10,000 Rxns) aliquots | A combination of the latest advances in buffer chemistry and PCR enhancers, together with a hot-start polymerase, dNTPs and MgCl2 and separate reverse transcriptas, ideal for fast, accurate, highly reproducible RT-qPCR. |
Yes | No | No | No | No | 2x | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
NGS Library Quantification | PCR, qPCR | NGS | MDX039 | Order a Sample | Available in 500 Rxns | Fast qPCR Mix, pre-diluted DNA standards, primer mix and dilution buffer, designed to accurately measure the number of amplifiable DNA fragments in Illumina-based NGS libraries before loading into a flow cell. |
Yes | No | No | No | No | 2x | No | View Details | Safety Data Sheet | Product Handling Guide | |||||
Lyo-Compatible MMLV-RT | Reverse Transcriptase, Air-Dryable & Lyo-Ready Enzymes | RT-qPCR | MDX042 | Order a Sample | Available in 8 µL (1,000 Rxns) or 80 µL (10,000 Rxns) aliquots | Glycerol-free high concentration reverse transcriptase and dilution buffer. Can be used to create 1-step RT-qPCR mixes for subsequent lyophilization. |
Yes | Requires excipients | Requires excipients | Yes | Requires excipients | > 165 U/µL | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
High-Specificity Pfu HS Mix | PCR, qPCR | NGS | MDX006 | Order a Sample | Available in 0.025 mL (500 Units) or 1 mL (20,000 Units) aliquots | High concentration, high-fidelity Taq DNA polymerase used for the amplification of a next-generation sequencing (NGS) library. |
Yes | No | No | No | No | 2x | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Glycerol-Free Taq HS, 50 U/µL | DNA Polymerase, Air-Dryable & Lyo-Ready Enzymes | PCR | MDX011 | Order a Sample | Available in 0.02 mL (1,000 Units) or 0.5 mL (25,000 Units) aliquots | Lyophilization-compatible high-performance Taq DNA polymerase, separate Taq antibody and enzyme dilution buffer, suitable for difficult, multiplex tests that require fast amplification, whilst maintaining high specificity and sensitivity. |
Yes | Requires excipients | Requires excipients | Yes | Requires excipients | 50 U/mL | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Bst DNA Polymerase | Isothermal DNA Polymerase, Bst Enzymes & Buffers | LAMP | MDX012 | Order a Sample | Available in 1 mL or 10 mL aliquots | DNA polymerase (exo-), with strand-displacement properties. used for Isothermal DNA amplification such as LAMP (Loop-mediated Isothermal Amplification). |
Yes | No | No | No | No | 8 units/mL | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Inhibitor-Tolerant qPCR Mix | Blood, saliva, urine, stool, tissue | qPCR | MDX013 | Order a Sample | Available in 5 mL (500 Rxns) or 100 mL (10,000 Rxns) aliquots | Universal inhibitor tolerant qPCR master mix, for direct amplification from crude lysates or inhibitor-rich samples such as urine, cerebral spinal fluid (CSF), blood, sputum, saliva and stool. |
Yes | No | No | No | No | 2x | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Aptamer Taq HS (Glycerol-Free) | DNA Polymerase, Air-Dryable & Lyo-Ready Enzymes | PCR | MDX015 | Order a Sample | Available in 20 ?L (1,000 Units) or 1 mL (50,000 Units) aliquots | Glycerol-free, high concentration hot-start Taq DNA polymerase, suitable for difficult, multiplex molecular tests that require fast amplification. |
Yes | Requires excipients | Requires excipients | Yes | Requires excipients | 50 U/mL | Yes | View Details | COA/Test Release | User Guide | Product Handling Guide | ||||
Inhibitor-Tolerant RT-qPCR Mix, 4x | Blood, saliva, urine, stool, tissue, RT-PCR, RT-qPCR | RT-qPCR | MDX016 | Order a Sample | Available in 5 mL (500 Rxns) or 50 mL (10,000 Rxns) aliquots | Universal, high concentration, inhibitor tolerant RT-qPCR master mix, for direct amplification from crude lysates or inhibitor-rich samples such as urine, cerebral spinal fluid (CSF), blood, sputum, saliva and stool. |
Yes | No | No | No | No | 4x | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
High Conc. Glycerol-Free Bst | Isothermal DNA Polymerase, Bst Enzymes & Buffers | LAMP | MDX018 | Order a Sample | Available in 80 µL or 800 µL aliquots | High concentration glycerol-free DNA polymerase (exo-), with strand-displacement properties. used for Isothermal DNA amplification such as LAMP (Loop-mediated Isothermal Amplification). |
Yes | Yes | Requires excipients | Yes | Yes | 100 units/mL | Yes | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Inhibitor-Tolerant Bst Buffer | Buffer, Bst Enzymes & Buffers | LAMP | MDX019 | Order a Sample | Available in 2 mL or 100 mL aliquots | Inhibitor-Tolerant Bst Buffer is specially designed to overcome the inhibition present in samples in direct LAMP reactions. |
Yes | Yes | Requires excipients | Yes | Yes | 10x | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Fast qPCR Mix | PCR, qPCR | qPCR | MDX020 | Order a Sample | Available in 5 mL (500 Rxns) or 100 mL (10,000 Rxns) aliquots | The latest advances in buffer chemistry and PCR enhancers and stabilizers, together with a hot-start polymerase, dNTPs and MgCl2, for highly reproducible, accurate assay results under fast thermal cycling conditions. |
Yes | No | No | No | No | 2x | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Lyo-Ready qPCR Mix | PCR, qPCR, Lyo-Ready Mix | qPCR | MDX021 | Order a Sample | Available in 5 mL (500 Rxns) or 100 mL (10,000 Rxns) aliquots | Glycerol-free Taq polymerase, reaction buffer, dNTP, MgCl2, and lyo-excipients, ideal for developing room temperature, lyophilized, multiplex qPCR assays. |
Yes | No | Lyo-Ready | Yes | Yes | 2x | No | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Lyo-Ready qPCR Buffer, 2.5x | Buffer, Air-Dryable & Lyo-Ready Enzymes | qPCR | MDX022 | Order a Sample | Available in 8 mL (500 Rxns) or 100 mL (12,500 Rxns) aliquots | Glycerol-free qPCR reaction buffer containing lyo-excipients, designed to deliver highly reproducible, accurate qPCR assay results under fast thermal cycling conditions. |
Yes | No | Lyo-Ready | Yes | Yes | 2.5x | No | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Lyo-Ready qPCR Mix 2.6x | PCR, qPCR, Lyo-Ready Mix | qPCR | MDX023 | Order a Sample | Available in 8 mL (500 Rxns) or 100 mL (12,500 Rxns) aliquots | Glycerol-free Taq polymerase, reaction buffer, dNTP, MgCl2, and lyo-excipients, ideal for developing room temperature, lyophilized, multiplex qPCR assays. |
Yes | No | Lyo-Ready | Yes | Yes | 2.6x | No | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide |
Not seeing what you’re looking for? Inquire about a new product
Molecular Master Mixes for PCR and Isothermal Amplification
They also ensure consistent results, with fewer pipetting steps and lower likelihood of mistakes or contamination and variability between wells and allowing more samples to be run in a day with the highest confidence, ideal for high-throughput assays.
- Fast cycling, reducing assay times.
- Superior sensitivity, specificity, and reproducibility.
- Lyophilization and air-dryable options.
- Compatible with automated, high-throughput instruments.
Meridian offers ready to use molecular master mixes for PCR and isothermal amplification, include master mixes formulated for direct use with crude lysates, and master mixes that can be lyophilized and air-dried.
Catalogs & Brochures
Specimen-specific™ and Universal qPCR & LAMP Master MixesSpecimen-specific™ and Universal qPCR & LAMP Master Mixes
Master Mixes for Molecular Ambient-Temperature Stable AssaysMaster Mixes for Molecular Ambient-Temperature Stable Assays
Lyo-Ready & Air-Dryable LAMP & RT-LAMP Master Mixes Lyo-Ready & Air-Dryable LAMP & RT-LAMP Master Mixes
Air-Dryable MixesAir-Dryable Mixes
Low LOD 1-Step RT-qPCR MixLow LOD 1-Step RT-qPCR Mix
Reagent Solutions for Molecular DiagnosticsReagent Solutions for Molecular Diagnostics
FAQ’s
Using molecular master mixes are convenient, reduces assay development times and pre-empt possible errors in mixing, making them ideal for high-throughput applications.
Master mixes usually contain enzymes (hot start polymerase/reverse transcriptase), an optimized buffer containing PCR enhancers, dNTPs, MgCl2, only template, primers, probes (if being used), and water, to make up the volume, normally need to be added.
Our master mixes are compatible with most standard cycling conditions and can also be used with very fast cycling conditions, however some optimization may be required for specific assay development.
There are several other advantages of one-step reactions, these include limited sample handling and reduced bench time, which helps to decrease chances for pipetting errors and cross contamination between reverse transcription and qPCR steps. This method is quick to set up and makes processing multiple RNA samples easy (especially when using liquid handling robotics), when you are amplifying only a few genes of interest. It is therefore ideal for high throughput screening laboratories where only a few reverse transcription qPCR assays are run repeatedly, using well-established reaction conditions, with the added advantage that multiplex qPCR of the gene of interest and control genes can be done in single well, from same RNA sample.
Yes, our PCR master mixes are designed to be used in multiplex assays. It is also possible to create a multiplex LAMP assay using different primers and probes, however they can be difficult to design and optimize as each sequence requires three sets of primers.
Yes, the Lyo-Ready and Air-Dryable master mixes can be used as liquid mixes or dried and stored at ambient temperature without needing to change the reaction conditions and drying/storage will not affect the sensitivity of the test.
It is stable for up to 2 years at ambient temperature if correctly stored in sealed pouches.
Get In Touch With A Specialist
Have questions about a product? Want to learn more about Meridian’s molecular or immunoassay reagent portfolio? We want to hear from you!