Ready-to-use PCR and high-fidelity PCR enzymes and DNA polymerases have been developed for fast PCR and are designed for superior sensitivity and yield. A combination of the latest advances in buffer chemistry and PCR enhancers, in conjunction with an antibody, aptamer, or chemical-mediated polymerases and DNA polymerases, promotes rapid, consistently accurate detection of DNA and cDNA targets. Glycerol-free options allow room temperature shipping and storage, extended shelf-life, and increased flexibility in sample volume, and isothermal options are available for loop-mediated isothermal amplification (LAMP).
Product Filters
Products (27)
Name | Details | Application | Catalog | Order a Sample | Sizes | Description | Wet(Liquid) | Air-Dryable | Name | Glycerol-Free | Lyo-Ready | Concentration | High Concentration | Detail | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | Product Manual | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Glycerol-Free Taq HS High Conc. DNA Polymerase | DNA Polymerase, NGS Enzymes, Air-Dryable & Lyo-Ready Enzymes | PCR | MDX170 | Order a Sample | Available in 0.025 mL (1,000 Units) or 0.5 mL (25,000 Units) aliquots | Glycerol-free, high concentration, high fidelity DNA polymerase with separate dilution and reaction buffer, ideal for NGS library amplification and gene expression. Ideal for lyophilization. |
Yes | Requires excipients | Requires excipients | Yes | Requires excipients | 50 U/µL | Yes | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Gycerol-free T4 DNA Ligase (HC) | NGS Enzymes, Air-Dryable & Lyo-Ready Enzymes | NGS | MDX200 | Order a Sample | Available in 1,000 Unit or 10,000 Unit aliquots | Glycerol-free, high concentration enzyme that efficiently joins blunt and cohesive ends and repairs single stranded nicks in duplex DNA, RNA or DNA/RNA hybrids. Ideal for lyophilization. |
Yes | Requires excipients | Requires excipients | Yes | Requires excipients | 50 Weiss unit/µL | Yes | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Glycerol-Free T7 RNA Polymerase (HC) | Isothermal Enzymes, Air-Dryable & Lyo-Ready Enzymes | NASBA | MDX201 | Order a Sample | Available in 50,000 Unit or 500,000 Unit aliquots | Glycerol-free, high concentration DNA-dependant RNA Polymerase that requires a T7 promoter sequence, it an ideal enzyme for in-vitro synthesis of labeled or unlabeled RNA for research, diagnostic or clinical applications. Ideal for lyophilization. |
Yes | Requires excipients | Requires excipients | Yes | Requires excipients | 1,000 U/µL | Yes | View Details | COA/Test Release | Product Handling Guide | |||||
Glycerol-Free RNase H (HC) | Reverse Transcriptase, NGS Enzymes, NASBA, Air-Dryable & Lyo-Ready Enzymes | RT-qPCR | MDX202 | Order a Sample | Available in 100 µL (2,500 Unit) or 250 µL (12,500 Unit) aliquots | Glycerol-free, high concentration RNA-specific endonuclease that hydrolyzes the phosphodiester bonds of RNA, when hybridized to DNA. Ideal for lyophilization. |
Yes | Requires excipients | Requires excipients | Yes | Requires excipients | 50 U/µL | Yes | View Details | COA/Test Release | Product Handling Guide | |||||
Glycerol-Free High-Fidelity Pfu (HC) | DNA Polymerase, NGS Enzymes, Air-Dryable & Lyo-Ready Enzymes | PCR | MDX203 | Order a Sample | Available in 0.025 mL (500 Units) or 1 mL (20,000 Units) aliquots | Glycerol-free, high concentration, high fidelity DNA polymerase with separate dilution and reaction buffer, ideal for NGS library amplification and gene expression. Ideal for lyophilization. |
Yes | Requires excipients | Requires excipients | Yes | Requires excipients | 20 U/µL | Yes | View Details | COA/Test Release | Product Handling Guide | |||||
Glycerol-Free HS Tth DNA Polymerase (HC) | DNA Polymerase, Reverse Transcriptase, Air-Dryable & Lyo-Ready Enzymes | RT-qPCR | MDX205 | Order a Sample | Available in 50 µL (4,000 Unit) or 500 µL (100,000 Unit) aliquots | Glycerol-free, high concentration, thermostable DNA polymerase with intrinsic reverse transcriptase (RT) activity and unlike other RT enzymes, it is not associated with RNase H activity. Ideal for lyophilization. |
Yes | Requires excipients | Requires excipients | Yes | Requires excipients | 200 U/µL | Yes | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Glycerol-Free T4 Polynucleotide Kinase (HC) | NGS Enzymes, Air-Dryable & Lyo-Ready Enzymes | NGS | MDX206 | Order a Sample | Available in 50 µL (500 Units) or 500 µL (5,000 Units) aliquots | Glycerol-free enzyme used to phosphorylate the ends of both DNA and RNA during labeling and ligation, mainly used in next-generation sequencing (NGS) library preparation. Ideal for lyophilization. |
Yes | Requires excipients | Requires excipients | Yes | Requires excipients | 20 U/µL | Yes | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Glycerol-Free T4 DNA Polymerase (HC) | NGS Enzymes, Air-Dryable & Lyo-Ready Enzymes | NGS | MDX207 | Order a Sample | Available in 50 µL (500 Units) or 500 µL (5,000 Units) aliquots | Glycerol-free, high concentration DNA polymerase used for generating blunt ends on any duplex DNA molecule, used in next-generation sequencing (NGS) library preparation. Ideal for lyophilization. |
Yes | Requires excipients | Requires excipients | Yes | Requires excipients | 20 U/µL | Yes | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Glycerol-Free DNA Pol I Klenow Fragment (HC) | NGS Enzymes, Air-Dryable & Lyo-Ready Enzymes | NGS | MDX208 | Order a Sample | Available in 200 µL (10,000 Units) or 1 mL (50,000 Units) aliquots | Glycerol-free, high concentration DNA polymerase used for generating blunt ends on any duplex DNA molecule, used in next-generation sequencing (NGS) library preparation. Ideal for lyophilization. |
Yes | Requires excipients | Requires excipients | Yes | Requires excipients | 20 U/µL | Yes | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Glycerol-Free DNA Pol I Klenow Fragment exo- (HC) | NGS Enzymes, Air-Dryable & Lyo-Ready Enzymes | NGS | MDX218 | Order a Sample | Available in 50 µL (10,000 Units) or 1 mL (50,000 Units) aliquots | Glycerol-free, high concentration DNA Pol I Klenow Fragment exo-, designed for dA- and dT-tailing for next-generation sequencing (NGS) adapter ligation and DNA sequencing by the Sanger method. |
Yes | Requires excipients | Requires excipients | Yes | Requires excipients | 20 U/µL | Yes | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Glycerol-Free Phi29 DNA Polymerase (HC) | Isothermal Enzymes, Air-Dryable & Lyo-Ready Enzymes | WGA | MDX240 | Order a Sample | Available in 20 µL (2,000 Unit) or 100 µL (10,000 Unit) aliquots | Glycerol-free, high concentration enzyme with exceptional strand displacement and processive synthesis properties, ideal for rolling-circle amplification (RCA). |
Yes | Requires excipients | Requires excipients | Yes | Requires excipients | 100 U/?L | Yes | View Details | |||||||
Glycerol-Free Thermostable DNA Helicase (HC) | Isothermal Enzymes, Air-Dryable & Lyo-Ready Enzymes | tHAD | MDX242 | Order a Sample | Available in 20 ?L (1 µg) or 200 ?L (10 µg) aliquots | Glycerol-free, high concentration enzyme used with in isothermal amplification method such as LAMP, RPA, RCA, SDA and tHDA) |
Yes | Requires excipients | Requires excipients | Yes | Requires excipients | 50 µg/mL | Yes | View Details | Product Handling Guide | ||||||
55C MMLV-RT | Reverse Transcriptase, Air-Dryable & Lyo-Ready Enzymes | RT-LAMP | MDX117 | Order a Sample | Available in 50 µL (10,000 Units), 200 µL (40,000 Units) or 1 mL (200,000 Units) aliquot | Highly robust, thermostable reverse transcriptase, ideal for cDNA synthesis from RNA with a high secondary structure such as viral RNA genomes. |
Yes | Requires excipients | Requires excipients | Yes | Requires excipients | 200 U/µL | Yes | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Uracil DNA Glycosylase | Others | qPCR | MDX054 | Order a Sample | Available in 10 mL (10,000 Rxns) aliquots | Used to eliminate carryover polymerase chain reaction (PCR) products in qPCR and RT-qPCR,by incorporating dUTP in reactions, so residual products from previous PCR amplifications containing dUs can be digested. |
Yes | No | No | No | No | 1 U/µL | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Proteinase K Solution | Others | Extraction | MDX055 | Order a Sample | Available in 25 mL aliquots | Proteinase K Solution is an enzyme used to digest most proteins in molecular biological techniques. |
Yes | No | No | No | No | 20 mg/mL | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Lyo-Compatible MMLV-RT | Reverse Transcriptase, Air-Dryable & Lyo-Ready Enzymes | RT-qPCR | MDX042 | Order a Sample | Available in 8 µL (1,000 Rxns) or 80 µL (10,000 Rxns) aliquots | Glycerol-free high concentration reverse transcriptase and dilution buffer. Can be used to create 1-step RT-qPCR mixes for subsequent lyophilization. |
Yes | Requires excipients | Requires excipients | Yes | Requires excipients | > 165 U/µL | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
RNase-Tolerant MMLV-RT | Reverse Transcriptase | RT-qPCR | MDX043 | Order a Sample | Available in 200 µL (1,000 Rxns) or 2 mL (10,000 Rxns) aliquots | For the detection of RNA at very low levels, it can also be used with a broader temperature range, making it ideal for applications such as blood bank or transplant viral testing. |
Yes | No | No | No | No | 100x | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
MMLV-RT | Reverse Transcriptase | RT-qPCR | MDX044 | Order a Sample | Available in 200 µL (1,000 Rxns) or 2 mL (10,000 Rxns) aliquots | For cDNA synthesis and subsequent PCR or qPCR in a one-step or two-step assay. |
Yes | No | No | No | No | 100x | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Taq DNA Polymerase | PCR | PCR | MDX001 | Order a Sample | Available in 0.5 mL (500 Units) or 10 mL (50,000 Units) aliquots | Very high yield, high-performance polymerase, to give fast, superior amplification, even with challenging templates and in the presence of PCR inhibitors. |
Yes | No | No | No | No | 5 U/mL | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
High-Fidelity Pfu | PCR, NGS Enzymes | PCR | MDX003 | Order a Sample | Available in 2 mL (500 Units) or 10 mL (25,000 Units) aliquots | Thermostable high fidelity Hot Start DNA polymerase, generates blunt-ended amplicons up to 5 kb in length making it ideal for high yields in NGS library amplification. |
Yes | No | No | No | No | 2 U/mL | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Taq HS DNA Polymerase | PCR | PCR | MDX008 | Order a Sample | Available in 0.1 mL (500 Units) or 10 mL (50,000 Units) aliquots | Very high yield, high-performance, antibody-mediated hot-start polymerase, to give fast, superior amplification, even with challenging templates and in the presence of PCR inhibitors. |
Yes | No | No | No | No | 5 U/mL | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Low DNA Taq HS 5 U/µL | PCR | PCR | MDX009 | Order a Sample | Available in 0.1 mL (500 Units) or 10 mL (50,000 Units) aliquots | Highly purified Taq DNA polymerase with low DNA background and stringent chemical hot-start properties, ideal for PCR of low-copy bacterial targets to avoid false-positive amplification, such as in water testing. |
Yes | No | No | No | No | 5 U/mL | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Glycerol-Free Taq HS, 50 U/µL | PCR, Air-Dryable & Lyo-Ready Enzymes | PCR | MDX011 | Order a Sample | Available in 0.02 mL (1,000 Units) or 0.5 mL (25,000 Units) aliquots | Lyophilization-compatible high-performance Taq DNA polymerase, separate Taq antibody and enzyme dilution buffer, suitable for difficult, multiplex tests that require fast amplification, whilst maintaining high specificity and sensitivity. |
Yes | Requires excipients | Requires excipients | Yes | Requires excipients | 50 U/mL | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
Bst DNA Polymerase | Isothermal DNA Polymerase, Bst Enzymes & Buffers | LAMP | MDX012 | Order a Sample | Available in 1 mL or 10 mL aliquots | DNA polymerase (exo-), with strand-displacement properties. used for Isothermal DNA amplification such as LAMP (Loop-mediated Isothermal Amplification). |
Yes | No | No | No | No | 8 units/mL | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Taq HS Antibody | Others | PCR | MDX014 | Order a Sample | Available in 20 µL (1,000 Units) or 250 µL (12,500 Units) aliquots | Mix of anti-Taq monoclonal antibodies designed to block Taq DNA polymerase activity at room temperature. Used in the preparation of hot-start PCR or qPCR master mixes. |
Yes | Requires excipients | Requires excipients | Yes | Requires excipients | 50 U/mL | Yes | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | ||||
Aptamer Taq HS (Glycerol-Free) | PCR, Air-Dryable & Lyo-Ready Enzymes | PCR | MDX015 | Order a Sample | Available in 20 ?L (1,000 Units) or 1 mL (50,000 Units) aliquots | Glycerol-free, high concentration hot-start Taq DNA polymerase, suitable for difficult, multiplex molecular tests that require fast amplification. |
Yes | Requires excipients | Requires excipients | Yes | Requires excipients | 50 U/mL | Yes | View Details | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | |||
High Conc. Glycerol-Free Bst | Isothermal DNA Polymerase, Bst Enzymes & Buffers, Air-Dryable & Lyo-Ready Enzymes | LAMP | MDX018 | Order a Sample | Available in 80 µL or 800 µL aliquots | High concentration glycerol-free DNA polymerase (exo-), with strand-displacement properties. used for Isothermal DNA amplification such as LAMP (Loop-mediated Isothermal Amplification). |
Yes | Yes | Requires excipients | Yes | Yes | 100 units/mL | Yes | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide |
Not seeing what you’re looking for? Inquire about a new product
Ready-to-Use PCR and High-Fidelity PCR Enzymes
Meridian also as a selection of reverse transcriptases for cDNA synthesis, including a reverse transcriptase for dealing with RNA that contains high amounts of secondary structure, such as RNA viruses and reverse transcriptase for dealing with crude samples, particularly in RT-PCR and RT-qPCR applications for the detection of very low-copy targets. We also have a high concentration lyophilization ready option, for incorporation into lyophilized RT-qPCR assays for room temperature shipping and storage, extending shelf-life and increased flexibility in sample volume.
We also have RNases and DNases free Proteinase K that exhibits broad cleavage specificity on native and denatured proteins and is widely used in the purification of native RNA and DNA from tissues or cell lines and it is especially suitable for isolating qPCR and RT-qPCR templates.
Core Enzymes for Nucleic Acid Processes
Catalogs & Brochures
Master Mixes for Molecular Ambient-Temperature Stable AssaysMaster Mixes for Molecular Ambient-Temperature Stable Assays
Air-Dryable MixesAir-Dryable Mixes
High-performing DNA polymerases CatalogHigh-performing DNA polymerases Catalog
A Comprehensive Guide to Essential Reagents for High-Throughput Molecular Diagnostic Assays (MDx)Accelerating Efficiency: A Comprehensive Guide to Essential Reagents for High-Throughput Molecular Diagnostic Assays (MDx)
Get In Touch With A Specialist
Have questions about a product? Want to learn more about Meridian’s molecular or immunoassay reagent portfolio? We want to hear from you!