Close
Frame

DNA-RNA Extraction Controls

Meridian’s DNA Extraction Controls use E. coli cells and RNA Extraction Controls use artificial micelles, of a known concentration that contain quantitative PCR positive control DNA or RNA sequence (with no known homology to any organism, so that it does not interfere with the detection of the sample target sequence). Their composition closely resembles a test sample and serves as a full-process PCR positive control, monitoring the success of an assay from lysis/extraction to amplification.
Product Filters

Clear All

Products (6)

Filters Close
Name Details Application Catalog Order a Sample Sizes Description Wet(Liquid) Air-Dryable Name Glycerol-Free Lyo-Ready Concentration High Concentration Detail Safety Data Sheet COA/Test Release User Guide Product Handling Guide
VLP-RNA Extraction Control Red VLP Extraction Controls RT-qPCR MDX068 Order a Sample Available in 1 mL (~1?10^4 copies/‘L) and 20 mL (~1?10^4 copies/‘L) aliquots

An Internal Control RNA sequence, with no known homology to any organism, encapsidated in a virus-like particle and a VLP Detection Mix containing primers and probe to the internal control RNA sequence.

Yes Requires excipients Air-Dryable,Lyo-Ready Yes Requires excipients 10^4 copies/‘L No
VLP-RNA Extraction Control Orange VLP Extraction Controls RT-qPCR MDX069 Order a Sample Available in 1 mL (~1?10^4 copies/‘L) and 20 mL (~1?10^4 copies/‘L) aliquots

An Internal Control RNA sequence, with no known homology to any organism, encapsidated in a virus-like particle and a VLP Detection Mix containing primers and probe to the internal control RNA sequence.

Yes Requires excipients Air-Dryable,Lyo-Ready Yes Requires excipients 10^4 copies/‘L No
qPCR Extraction Control Red Extraction Controls qPCR MDX026 Order a Sample Available in 10 mL (2,000 Rxns) aliquots

Control used to monitor the success of a qPCR assay from lysis/extraction to amplification and reduces the chance of obtaining false negative results from the sample DNA.

Yes No No No No 25x No
qPCR Extraction Control Orange Extraction Controls qPCR MDX027 Order a Sample Available in 10 mL (2,000 Rxns) aliquots

Control used to monitor the success of a qPCR assay from lysis/extraction to amplification and reduces the chance of obtaining false negative results from the sample DNA.

Yes No No No No 25x No
RT-qPCR Extraction Control Red Extraction Controls RT-qPCR MDX028 Order a Sample Available in 1 mL (500 Rxns) aliquots

Control used to monitor the success of an RT-qPCR assay from lysis/extraction to amplification and reduces the chance of obtaining false negative results from the sample RNA.

Yes No No No No 25x No
RT-qPCR Extraction Control Orange Extraction Controls RT-qPCR MDX029 Order a Sample Available in 1 mL (500 Rxns) aliquots

Control used to monitor the success of an RT-qPCR assay from lysis/extraction to amplification and reduces the chance of obtaining false negative results from the sample RNA.

Yes No No No No 25x No

Not seeing what you’re looking for? Inquire about a new product

Why We Are Second To None

Meridian offers diagnostic manufacturers the complete solution with over 3,000 antigens and antibodies covering more than 500 diseases and an extensive range of specialty qPCR/RT-qPCR master mixes and molecular enzymes all manufactured under ISO13485 regulations.

  • Path Copy

    Large Sample Size

  • Lot Reservation

    Lot Reservation

  • ISO13485

    ISO13485

  • World-Class Customer Service

    World-Class Customer Service

  • Extraction control undergoes the same processing as test sample.
  • Confirms successes of extraction step and monitors co-purification of PCR inhibitors.
  • Probe based designed specifically for multiplex qPCR/RT-qPCR assays.

The extraction controls comprise an internal control sequence in use E. coli cells or artificial micelles and a control mix (containing specific primer and probe (emission wavelength = 560nm or 670nm)) for qPCR detection. The cells are added to the sample or lysis buffer and lysed and extracted with the sample for downstream amplification. The detection of extraction control acts as a PCR positive control and confirms the success of the extraction and amplification steps, avoiding the misinterpretation of a PCR false negative result.

FAQ's

The benefit of the artificial Extraction Control in evaluation of the extraction process is the possibility to validate sample extraction process. Signal derived from the Extraction Control confirms the success of the extraction step and monitors co-purification of PCR inhibitors that may cause biased or PCR false negative results. Housekeeping genes or spike in controls do not monitor the whole extraction process, especially the lysis step and in the case of housekeeping genes, extraction efficiency and degraded samples as well as the possibility of the housekeeping gene expression level changing.

The primers and probe for the Extraction Controls are in the Control Mix.

The two colors are for the fluorescent dyes on the Extraction Control probe. Control Mix Red (Cy5 – emission wavelength = 670nm) and Control Mix Orange (HEX – emission wavelength = 560nm). This allows you to choose one that will fit with your existing protocol in a multiplex assay.

No, the Extraction Control will work with commercially available silica-membrane extraction kits and CHELEX matrices and has been tested on a wide range of qPCR platforms.

Get In Touch With A Specialist

Have questions about a product? Want to learn more about Meridian’s molecular or immunoassay reagent portfolio? We want to hear from you!


By submitting your information in this form, you agree that your personal information may be stored and processed in any country where we have facilities or service providers, and by using our “Contact Us” page you agree to the transfer of information to countries outside of your country of residence, including to the United States, which may provide for different data protection rules than in your country. The information you submit will be governed by our Privacy Statement.

Learn More About Us

About
Welcome to
logo blue

Please select your country to continue

Continue
CN