Molecular diagnostic tests are progressively moving towards lyophilized and air-dried formats. There are several advantages for this, including room temperature shipping and storage, extended shelf-life, and increased flexibility in sample volume. However, to be compatible with drying, enzyme preparations must be glycerol-free and include specialized excipients that preserve the mixture as it is exposed to various conditions, including freezing, temperature ramps, vacuum, and dehydration.
Product Filters
Specimen Type
Application
Dryable
High Concentration
Clear All

Products (75)

FiltersClose
NameDetailsApplicationCatalogOrder a SampleSizesDescriptionWet(Liquid)Air-DryableNameGlycerol-FreeLyo-ReadyConcentrationHigh ConcentrationDetailSafety Data SheetCOA/Test ReleaseUser GuideProduct Handling GuideProduct Manual
Lyo-Ready AOF dUTP RNA/DNA qPCR UrineUrine, RNART-qPCRMDX353Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsAn optimized RT-qPCR master mix tolerant to inhibitors in urine. Perfect for multiplexing, high throughput assays where there is a greater risk of false positives from cross-over contamination.YesYesLyo-ReadyYesYes4xYes
Lyo-Ready AOF dUTP DNA qPCR UrineDNAqPCRMDX352Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsAn optimized qPCR master mix tolerant to inhibitors in urine. Perfect for multiplexing, high throughput assays where there is a greater risk of false positives from cross-over contamination.YesYesLyo-ReadyYesYes4xYes
Lyo-Ready AOF dUTP RNA/DNA qPCR SalivaSaliva, Sputum, RNART-qPCRMDX333Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsAn optimized RT-qPCR master mix tolerant to inhibitors in saliva and sputum. Perfect for multiplexing, high throughput assays where there is a greater risk of false positives from cross-over contamination.YesYesLyo-ReadyYesYes4xYes
Lyo-Ready AOF dUTP DNA qPCR SalivaSaliva, Sputum, DNAqPCRMDX332Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsAn optimized qPCR master mix tolerant to inhibitors in saliva and sputum. Perfect for multiplexing, high throughput assays where there is a greater risk of false positives from cross-over contamination.YesYesLyo-ReadyYesYes4xYes
Lyo-Ready AOF dUTP RNA/DNA qPCR BloodBlood, Plasma, Serum, RNART-qPCRMDX323Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsAn optimized RT-qPCR master mix tolerant to inhibitors in whole blood and plasma and compatible with all anticoagulants. Perfect for multiplexing, high throughput assays where there is a greater risk of false positives from cross-over contamination.YesYesLyo-ReadyYesYes4xYes
Lyo-Ready AOF dUTP DNA qPCR BloodBlood, Plasma, Serum, DNAqPCRMDX322Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsAn optimized qPCR master mix tolerant to inhibitors in whole blood and plasma and compatible with all anticoagulants. Perfect for multiplexing, high throughput assays where there is a greater risk of false positives from cross-over contamination.YesYesLyo-ReadyYesYes4xYes
Glycerol-Free Thermostable DNA Helicase (HC)DNALAMP, RPA, RCA, SDAMDX242Order a SampleAvailable in 20 µL (1 µg) or 200 µL (10 µg) aliquotsGlycerol-free, high concentration enzyme used to unwind double-stranded DNA. It operates at up to 65°C, ideal for demanding diagnostic workflows such as NGS library preparation, SNP detection and mutation analysisYesYesRequires excipientsYesYes50 µg/mLYes
Glycerol-Free Phi29 DNA Polymerase (HC)DNARCA, WGAMDX240Order a SampleAvailable in 20 µL (2,000 Unit) or 100 µL (10,000 Unit) aliquotsGlycerol-free, high concentration enzyme with exceptional strand displacement and processive synthesis properties, ideal for rolling-circle amplification (RCA).YesYesRequires excipientsYesYes100 U/?LYes
Lyo-Ready Inhibitor-Tolerant qPCR MixBlood, saliva, urine, stool, tissue, DNAqPCRMDX184Order a SampleAvailable in 1,000 Unit or 10,000 Unit aliquotsUniversal, high concentration, inhibitor tolerant qPCR master mix, for direct amplification from crude lysates or inhibitor-rich samples such as urine, cerebral spinal fluid (CSF), blood, sputum, saliva and stool.YesYesLyo-ReadyYesYes4xYes
Lyo-Ready Direct DNA LAMP Urine, 4xUrine, DNALAMPMDX154Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsInhibitor tolerance to 20% urine. Perfect for multiplexing and fast cycling conditions. Used in the detection of urinary track infections, STD, tropical diseases, cancer screening, bladder and prostate cancer.YesYesLyo-ReadyYesYes4xYes
Lyo-Ready Direct RNA/DNA LAMP Urine, 4xUrine, RNART-LAMPMDX155Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsInhibitor tolerance to 20% urine. Perfect for multiplexing and fast cycling conditions. Used in the detection of urinary track infections, STD, tropical diseases, cancer screening, bladder and prostate cancer.YesYesLyo-ReadyYesYes4xYes
Lyo-Ready Genotyping Direct qPCR Urine, 4xUrine, DNASNP GenotypingMDX158Order a SampleAvailable in 1,000 Unit or 10,000 Unit aliquotsInhibitor tolerance to 20% urine. Compatible with all dual-label probe chemistries for detection of genetic variants, such as single nucleotide and copy number variants, to give highly reproducible allelic discrimination.YesYesLyo-ReadyYesYes4xYes
Lyo-Ready Genotyping Direct qPCR FFPE, 4xFFPE, DNASNP GenotypingMDX168Order a SampleAvailable in 1,000 Unit or 10,000 Unit aliquotsBetter extraction buffers and greater tolerance to crude FFPE samples. Compatible with all dual-label probe chemistries for detection of genetic variants, such as single nucleotide and copy number variants, to give highly reproducible allelic discrimination.YesYesLyo-ReadyYesYes4xYes
Glycerol-Free Taq HS High Conc. DNA PolymeraseDNAPCR, NGSMDX170Order a SampleAvailable in 0.025 mL (1,000 Units) or 0.5 mL (25,000 Units) aliquotsGlycerol-free, high concentration, high fidelity DNA polymerase with separate dilution and reaction buffer, ideal for NGS library amplification and gene expression. Ideal for lyophilization.YesYesRequires excipientsYesYes50 U/µLYes
Lyo-Ready Inhibitor-Tolerant RT-qPCR MixBlood, saliva, urine, stool, tissue, RNART-qPCRMDX185Order a SampleAvailable in 1,000 Unit or 10,000 Unit aliquotsUniversal, high concentration, inhibitor tolerant RT-qPCR master mix, for direct amplification from crude lysates or inhibitor-rich samples such as urine, cerebral spinal fluid (CSF), blood, sputum, saliva and stool.YesYesLyo-ReadyYesYes4xYes
Gycerol-free T4 DNA Ligase (HC)DNANGSMDX200Order a SampleAvailable in 1,000 Unit or 10,000 Unit aliquotsGlycerol-free, high concentration enzyme that efficiently joins blunt and cohesive ends and repairs single stranded nicks in duplex DNA, RNA or DNA/RNA hybrids. Ideal for lyophilization.YesYesRequires excipientsYesYes50 Weiss unit/µLYes
Glycerol-Free RNase H (HC)RNART-qPCRMDX202Order a SampleAvailable in 100 µL (2,500 Unit) or 250 µL (12,500 Unit) aliquotsGlycerol-free, high concentration RNA-specific endonuclease that hydrolyzes the phosphodiester bonds of RNA, when hybridized to DNA. Ideal for lyophilization.YesYesRequires excipientsYesYes50 U/µLYes
Glycerol-Free High-Fidelity Pfu (HC)DNAPCRMDX203Order a SampleAvailable in 0.025 mL (500 Units) or 1 mL (20,000 Units) aliquotsGlycerol-free, high concentration, high fidelity DNA polymerase with separate dilution and reaction buffer, ideal for NGS library amplification and gene expression. Ideal for lyophilization.YesYesRequires excipientsYesYes20 U/µLYes
Glycerol-Free T7 RNA Polymerase (HC)RNANASBAMDX201Order a SampleAvailable in 50,000 Unit or 500,000 Unit aliquotsGlycerol-free, high concentration DNA-dependant RNA Polymerase that requires a T7 promoter sequence, it an ideal enzyme for in-vitro synthesis of labeled or unlabeled RNA for research, diagnostic or clinical applications. Ideal for lyophilization.YesYesRequires excipientsYesYes1,000 U/µLYes
Glycerol-Free HS Tth DNA Polymerase (HC)DNA, RNART-qPCRMDX205Order a SampleAvailable in 50 µL (4,000 Unit) or 500 µL (100,000 Unit) aliquotsGlycerol-free, high concentration, thermostable DNA polymerase with intrinsic reverse transcriptase (RT) activity and unlike other RT enzymes, it is not associated with RNase H activity. Ideal for lyophilization.YesYesRequires excipientsYesYes200 U/µLYes
Glycerol-Free T4 Polynucleotide Kinase (HC)DNANGSMDX206Order a SampleAvailable in 25 µL (500 Units) or 250 µL (5,000 Units) aliquotsGlycerol-free enzyme used to phosphorylate the ends of both DNA and RNA during labeling and ligation, mainly used in next-generation sequencing (NGS) library preparation. Ideal for lyophilization.YesYesRequires excipientsYesYes20 U/µLYes
Glycerol-Free T4 DNA Polymerase (HC)DNANGSMDX207Order a SampleAvailable in 50 µL (500 Units) or 500 µL (5,000 Units) aliquotsGlycerol-free, high concentration DNA polymerase used for generating blunt ends on any duplex DNA molecule, used in next-generation sequencing (NGS) library preparation. Ideal for lyophilization.YesYesRequires excipientsYesYes20 U/µLYes
Glycerol-Free DNA Pol I Klenow Fragment (HC)DNANGSMDX208Order a SampleAvailable in 200 µL (10,000 Units) or 1 mL (50,000 Units) aliquotsGlycerol-free, high concentration DNA polymerase used for generating blunt ends on any duplex DNA molecule, used in next-generation sequencing (NGS) library preparation. Ideal for lyophilization.YesYesRequires excipientsYesYes50 U/µLYes
Glycerol-Free DNA Pol I Klenow Fragment exo- (HC)DNANGSMDX218Order a SampleAvailable in 50 µL (10,000 Units) or 1 mL (50,000 Units) aliquotsGlycerol-free, high concentration DNA Pol I Klenow Fragment exo-, designed for dA- and dT-tailing for next-generation sequencing (NGS) adapter ligation and DNA sequencing by the Sanger method.YesYesRequires excipientsYesYes20 U/µLYes
Lyo-Ready Direct DNA LAMP Saliva, 4xSaliva, Sputum, DNALAMPMDX134Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsInhibitor tolerance to 60% crude saliva, sputum or mucin samples and 50% UTM. Perfect for multiplexing and fast cycling conditions. Used in the detection of a broad range of diseases, including cancer, respiratory viruses and bacterial infections.YesYesLyo-ReadyYesYes4xYes
Lyo-Ready Direct RNA/DNA LAMP Saliva, 4xSaliva, Sputum, RNART-LAMPMDX135Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsInhibitor tolerance to 60% crude saliva, sputum or mucin samples and 50% UTM. Perfect for multiplexing and fast cycling conditions. Used in the detection of a broad range of diseases, including cancer, respiratory viruses and bacterial infections.YesYesLyo-ReadyYesYes4xYes
Air-Dryable Direct DNA qPCR Stool, 4xStool, DNAqPCRMDX140Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsInhibitor tolerance to 20% stool, 2 mg/mL bile salt and 40% Cary Blair media. Perfect for multiplexing and fast cycling conditions. Used in the detection of IBD, cancer, fecal microbiota and bacterial and viruses.YesYesAir-DryableYesNo4xYes
Air-Dryable Direct RNA/DNA qPCR Stool, 4xStool, RNART-qPCRMDX141Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsInhibitor tolerance to 5% stool, 2 mg/mL bile salt and 40% Cary Blair media. Perfect for multiplexing and fast cycling conditions. Used in the detection of IBD, cancer, fecal microbiota and bacterial and viruses.YesYesAir-DryableYesNo4xYes
Lyo-Ready Direct DNA qPCR Stool, 4xStool, DNAqPCRMDX142Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsInhibitor tolerance to 20% stool, 2 mg/mL bile salt and 40% Cary Blair media. Perfect for multiplexing and fast cycling conditions. Used in the detection of IBD, cancer, fecal microbiota and bacterial and viruses.YesYesLyo-ReadyYesYes4xYes
Lyo-Ready Direct RNA/DNA qPCR Stool, 4xStool, RNART-qPCRMDX143Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsInhibitor tolerance to 5% stool, 2 mg/mL bile salt and 40% Cary Blair media. Perfect for multiplexing and fast cycling conditions. Used in the detection of IBD, cancer, fecal microbiota and bacterial and viruses.YesYesLyo-ReadyYesYes4xYes
Lyo-Ready Direct DNA LAMP Stool, 4xStool, DNALAMPMDX144Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsInhibitor tolerance to 20% stool, 2 mg/mL bile salt and 40% Cary Blair media. Perfect for multiplexing and fast cycling conditions. Used in the detection of IBD, cancer, fecal microbiota and bacterial and viruses.YesYesLyo-ReadyYesYes4xYes
Lyo-Ready Direct RNA/DNA LAMP Stool, 4xStool, RNART-LAMPMDX145Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsInhibitor tolerance to 5% stool, 2 mg/mL bile salt and 40% Cary Blair media. Perfect for multiplexing and fast cycling conditions. Used in the detection of IBD, cancer, fecal microbiota and bacterial and viruses.YesYesLyo-ReadyYesYes4xYes
Lyo-Ready Genotyping Direct qPCR Stool, 4xStool, DNASNP GenotypingMDX148Order a SampleAvailable in 1,000 Unit or 10,000 Unit aliquotsInhibitor tolerance to 20% stool. Compatible with all dual-label probe chemistries for detection of genetic variants, such as single nucleotide and copy number variants, to give highly reproducible allelic discrimination.YesYesLyo-ReadyYesYes4xYes
Air-Dryable Direct DNA qPCR Urine, 4xUrine, DNAqPCRMDX150Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsInhibitor tolerance to 60% urine. Perfect for multiplexing and fast cycling conditions. Used in the detection of urinary track infections, STD, tropical diseases, cancer screening, bladder and prostate cancer.YesYesAir-DryableYesNo4xYes
Air-Dryable Direct RNA/DNA qPCR Urine, 4xUrine, RNART-qPCRMDX151Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsInhibitor tolerance to 20% urine. Perfect for multiplexing and fast cycling conditions. Used in the detection of urinary track infections, STD, tropical diseases, cancer screening, bladder and prostate cancer.YesYesAir-DryableYesNo4xYes
Lyo-Ready Direct DNA qPCR Urine, 4xUrine, DNAqPCRMDX152Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsInhibitor tolerance to 20% urine. Perfect for multiplexing and fast cycling conditions. Used in the detection of urinary track infections, STD, tropical diseases, cancer screening, bladder and prostate cancer.YesYesLyo-ReadyYesYes4xYes
Lyo-Ready Direct RNA/DNA qPCR Urine, 4xUrine, RNART-qPCRMDX153Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsInhibitor tolerance to 20% urine. Perfect for multiplexing and fast cycling conditions. Used in the detection of urinary track infections, STD, tropical diseases, cancer screening, bladder and prostate cancer.YesYesLyo-ReadyYesYes4xYes
Lyo-Ready Direct RNA/DNA qPCR Saliva, 4xSaliva, Sputum, RNART-qPCRMDX133Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsInhibitor tolerance to 60% crude saliva, sputum or mucin samples and 50% UTM. Perfect for multiplexing and fast cycling conditions. Used in the detection of a broad range of diseases, including cancer, respiratory viruses and bacterial infections.YesYesLyo-ReadyYesYes4xYes
Lyo-Ready Direct DNA qPCR Saliva, 4xSaliva, Sputum, DNAqPCRMDX132Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsInhibitor tolerance to 60% crude saliva, sputum or mucin samples and 50% UTM. Perfect for multiplexing and fast cycling conditions. Used in the detection of a broad range of diseases, including cancer, respiratory viruses and bacterial infections.YesYesLyo-ReadyYesYes4xYes
Air-Dryable Direct RNA/DNA qPCR Saliva, 4xSaliva, Sputum, RNART-qPCRMDX131Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsInhibitor tolerance to 60% crude saliva, sputum or mucin samples and 50% UTM. Perfect for multiplexing and fast cycling conditions. Used in the detection of a broad range of diseases, including cancer, respiratory viruses and bacterial infections.YesYesAir-DryableYesNo4xYes
Air-Dryable Direct DNA qPCR Saliva, 4xSaliva, Sputum, DNAqPCRMDX130Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsInhibitor tolerance to 60% crude saliva, sputum or mucin samples and 50% UTM. Perfect for multiplexing and fast cycling conditions. Used in the detection of a broad range of diseases, including cancer, respiratory viruses and bacterial infections.YesYesAir-DryableYesNo4xYes
Lyo-Ready Genotyping Direct qPCR Blood, 4xBlood, Plasma, Serum, DNASNP GenotypingMDX128Order a SampleAvailable in 1,000 Unit or 10,000 Unit aliquotsInhibitor tolerance to 10% whole blood, 20% plasma. Compatible with all dual-label probe chemistries for detection of genetic variants, such as single nucleotide and copy number variants, to give highly reproducible allelic discrimination.YesYesLyo-ReadyYesYes4xYes
Air-Dryable Direct DNA LAMP Blood, 4xBlood, Plasma, Serum, DNALAMPMDX126Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsInhibitor tolerance to 10% whole blood, 10% plasma, compatible with all anticoagulants. Perfect for multiplexing and fast cycling conditions. Used in the detection of blood pathogens and liquid biopsy applications.YesYesAir-DryableYesNo4xYes
Lyo-Ready Direct RNA/DNA LAMP Blood, 4xBlood, Plasma, Serum, RNART-LAMPMDX125Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsInhibitor tolerance to 10% whole blood, 10% plasma, compatible with all anticoagulants. Perfect for multiplexing and fast cycling conditions. Used in the detection of blood pathogens and liquid biopsy applications.YesYesLyo-ReadyYesYes4xYes
Air-Dryable 1-Step RT-qPCR Mix, 4xRNART-qPCRMDX095Order a SampleAvailable in 5 mL (500 Rxns) or 50 mL (10,000 Rxns) aliquotsGlycerol-free RT-qPCR mix containing Taq polymerase, reverse transcriptase, reaction buffer, dNTPs, MgCl2 and air-dry compatible excipients, ideal for developing ambient temperature, multiplex molecular assays.YesYesAir-DryableYesNo4xYes
Air-Dryable qPCR Mix, 4xDNAqPCRMDX082Order a SampleAvailable in 5 mL (500 Rxns) or 50 mL (10,000 Rxns) aliquotsGlycerol-free qPCR mix containing Taq polymerase, reaction buffer, dNTPs, MgCl2 and air-dry compatible excipients, ideal for developing ambient temperature, multiplex molecular assays.YesYesAir-DryableYesNo4xYes
Air-Dryable Direct DNA qPCR Blood, 4xBlood, Plasma, Serum, DNAqPCRMDX092Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsInhibitor tolerance to 20% whole blood, 20% plasma, compatible with all anticoagulants. Perfect for multiplexing and fast cycling conditions. Used in the detection of blood pathogens and liquid biopsy applications.YesYesAir-DryableYesNo4xYes
Lyo-Ready LAMP Mix, 4xDNALAMPMDX097Order a SampleAvailable in 5 mL (800 Rxns) or 50 mL (8,000 Rxns) aliquotsGlycerol-free mix for isothermal applications such as LAMP, containing Bst DNA polymerase, reaction buffer, dNTPs and lyo-compatible excipients, ideal for developing ambient temperature, LAMP assays.YesYesLyo-ReadyYesYes4xYes
Lyo-Ready RT-LAMP 1-Step Mix, 4xRNART-LAMPMDX108Order a SampleAvailable in 5 mL (800 Rxns) or 50 mL (8,000 Rxns) aliquotsGlycerol-free mix for isothermal applications such as RT-LAMP, containing Bst DNA polymerase, reverse transcriptase, reaction buffer, dNTPs and lyo-compatible excipients, ideal for developing ambient temperature, LAMP assays.YesYesLyo-ReadyYesYes4xYes
Lyo-Ready dUTP 1-Step RT-qPCR MixRNART-qPCRMDX113Order a SampleAvailable in 10 mL (1,000 Rxns) or 100 mL (10,000 Rxns) aliquotsGlycerol-free mix containing Taq polymerase, RNase Inhibitor, reaction buffer, dNTP/dUTP mix, MgCl2 and lyo-excipients and separate reverse transcriptase , developed to remove background PCR product contamination.YesYesLyo-ReadyYesYes2xYes
Air-Dryable Direct DNA qPCR Plant, 4xPlant, DNAqPCRMDX116Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsNo need for extraction, compatible with 25% Plant lysate (SDS, NaOH). Perfect for multiplexing and fast cycling conditions for in-field qPCR testing. Used for genotyping and transgene or pathogenic detection.YesYesAir-DryableYesNo4xYes
Air-Dryable RT-LAMP 1-Step Mix, 4xRNART-LAMPMDX118Order a SampleAvailable in 5 mL (800 Rxns) or 50 mL (8,000 Rxns) aliquotsGlycerol-free mix for isothermal applications such as RT-LAMP, containing Bst DNA polymerase, reverse transcriptase, reaction buffer, dNTPs and air-dryable excipients, ideal for developing ambient temperature, LAMP assays.YesYesAir-DryableYesNo4xYes
Air-Dryable DNA LAMPDNALAMPMDX119Order a SampleAvailable in 5 mL (800 Rxns) or 50 mL (8,000 Rxns) aliquotsGlycerol-free mix for isothermal applications such as LAMP, containing Bst DNA polymerase, reaction buffer, dNTPs and air-dryable excipients, ideal for developing ambient temperature, LAMP assays.YesYesAir-DryableYesNo4xYes
Air-Dryable Direct RNA/DNA qPCR Blood, 4xBlood, Plasma, Serum, RNART-qPCRMDX121Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsInhibitor tolerance to 10% whole blood, 10% plasma, compatible with all anticoagulants. Perfect for multiplexing and fast cycling conditions. Used in the detection of blood pathogens and liquid biopsy applications.YesYesAir-DryableYesNo4xYes
Lyo-Ready Direct DNA qPCR Blood, 4xBlood, Plasma, Serum, DNAqPCRMDX122Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsInhibitor tolerance to 20% whole blood, 20% plasma, compatible with all anticoagulants. Perfect for multiplexing and fast cycling conditions. Used in the detection of blood pathogens and liquid biopsy applications.YesYesLyo-ReadyYesYes4xYes
Lyo-Ready Direct RNA/DNA qPCR Blood, 4xBlood, Plasma, Serum, RNART-qPCRMDX123Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsInhibitor tolerance to 10% whole blood, 10% plasma, compatible with all anticoagulants. Perfect for multiplexing and fast cycling conditions. Used in the detection of blood pathogens and liquid biopsy applications.YesYesLyo-ReadyYesYes4xYes
Lyo-Ready Direct DNA LAMP Blood, 4xBlood, Plasma, Serum, DNALAMPMDX124Order a SampleAvailable in 5 mL (1,000 Rxns) or 50 mL (10,000 Rxns) aliquotsInhibitor tolerance to 20% whole blood, 20% plasma, compatible with all anticoagulants. Perfect for multiplexing and fast cycling conditions. Used in the detection of blood pathogens and liquid biopsy applications.YesYesLyo-ReadyYesYes4xYes
55C MMLV-RTRNART-qPCR, RT-LAMPMDX117Order a SampleAvailable in 50 µL (10,000 Units), 200 µL (40,000 Units) or 1 mL (200,000 Units) aliquotHighly robust, thermostable reverse transcriptase, ideal for cDNA synthesis from RNA with a high secondary structure such as viral RNA genomes.YesYesRequires excipientsYesYes200 U/µLYes
Lyo-Ready 1-Step RT-qPCR Virus MixRNART-qPCRMDX062Order a SampleAvailable in 10 mL (1,000 Rxns) or 100 mL (10,000 Rxns) aliquotsTaq polymerase, RNase inhibitor, reaction buffer, dNTP, MgCl2 and lyo-excipients and separate reverse transcriptase, optimized for amplification of RNA with high secondary structure.YesYesLyo-ReadyYesYes2xYes
Lyo-Ready qPCR Buffer w/o Excipients, 4xDNAqPCRMDX061Order a SampleAvailable in 2.5 mL (500 Rxns) or 100 mL (20,000 Rxns) aliquotsGlycerol-free qPCR reaction buffer that is designed to allow formulation optimization to freeze-drying methods by excipients selection.YesYesAir-Dryable,Lyo-ReadyYesYes4xYes
Lyo-Ready 1-Step RT-qPCR BufferRNART-qPCRMDX052Order a SampleAvailable in 10 mL (1,000 Rxns) or 100 mL (10,000 Rxns) aliquotsGlycerol-free RT-qPCR reaction buffer containing lyo-excipients, designed to deliver highly reproducible, accurate RT-qPCR assay results under fast thermal cycling conditions.YesYesLyo-ReadyYesYes2xYes
Lyo-Compatible MMLV-RTRNART-qPCRMDX042Order a SampleAvailable in 8 µL (1,000 Rxns) or 80 µL (10,000 Rxns) aliquotsGlycerol-free high concentration reverse transcriptase and dilution buffer. Can be used to create 1-step RT-qPCR mixes for subsequent lyophilization.YesYesRequires excipientsYesYes> 165 U/µLYes
Lyo-Ready 1-Step RT-qPCR MixRNART-qPCRMDX024Order a SampleAvailable in 10 mL (1,000 Rxns) or 100 mL (10,000 Rxns) aliquotsGlycerol-free Taq polymerase, reaction buffer, dNTP, MgCl2, and lyo-excipients, and separate thermostable reverse transcriptase, ideal for developing room temperature, lyophilized, multiplex qPCR assays.YesYesLyo-ReadyYesYes2xYes
dATP, 100mM (Lithium)DNAqPCRMDX046Order a SampleAvailable in 50 mL aliquotsUltra-pure dATP (2’-Deoxyadenosine-5’-Triphosphate) lithium salt solution, enzymatically synthesized from premium quality raw materials.YesYesAir-Dryable,Lyo-ReadyYesYes100 mMYes
Lyo-Ready qPCR Mix 2.6xDNAqPCRMDX023Order a SampleAvailable in 8 mL (500 Rxns) or 100 mL (12,500 Rxns) aliquotsGlycerol-free Taq polymerase, reaction buffer, dNTP, MgCl2, and lyo-excipients, ideal for developing room temperature, lyophilized, multiplex qPCR assays.YesYesLyo-ReadyYesYes2.6xYes
Lyo-Ready qPCR Buffer, 2.5xDNAqPCRMDX022Order a SampleAvailable in 8 mL (500 Rxns) or 100 mL (12,500 Rxns) aliquotsGlycerol-free qPCR reaction buffer containing lyo-excipients, designed to deliver highly reproducible, accurate qPCR assay results under fast thermal cycling conditions.YesYesLyo-ReadyYesYes2.5xYes
Lyo-Ready qPCR MixDNAqPCRMDX021Order a SampleAvailable in 5 mL (500 Rxns) or 100 mL (10,000 Rxns) aliquotsGlycerol-free Taq polymerase, reaction buffer, dNTP, MgCl2, and lyo-excipients, ideal for developing room temperature, lyophilized, multiplex qPCR assays.YesYesLyo-ReadyYesYes2xYes
High Conc. Glycerol-Free BstDNALAMPMDX018Order a SampleAvailable in 80 µL or 800 µL aliquotsHigh concentration glycerol-free DNA polymerase (exo-), with strand-displacement properties. used for Isothermal DNA amplification such as LAMP (Loop-mediated Isothermal Amplification).YesYesRequires excipientsYesYes100 units/mLYes
Aptamer Taq HS (Glycerol-Free)DNAPCRMDX015Order a SampleAvailable in 20 ?L (1,000 Units) or 1 mL (50,000 Units) aliquotsGlycerol-free, high concentration hot-start Taq DNA polymerase, suitable for difficult, multiplex molecular tests that require fast amplification.YesYesRequires excipientsYesYes50 U/mLYes
Glycerol-Free Taq HS, 50 U/µLDNAPCRMDX011Order a SampleAvailable in 0.02 mL (1,000 Units) or 0.5 mL (25,000 Units) aliquotsLyophilization-compatible high-performance Taq DNA polymerase, separate Taq antibody and enzyme dilution buffer, suitable for difficult, multiplex tests that require fast amplification, whilst maintaining high specificity and sensitivity.YesYesRequires excipientsYesYes50 U/mLYes
Lyo-Ready Direct RNA NASBA BloodBlood, Plasma, Serum, RNANASBAMDX220Order a SampleAvailable in 400 mL (50 Rxns) or 2 mL (250 Rxns) aliquotsSingle pot, one-step Nucleic Acid Sequence-Based Amplification (NASBA) for reliable isothermal amplification of RNA transcripts from crude or purified blood samples, ideal for POC testingYesYesLyo-ReadyYesYes2.5xYes
Glycerol-Free DNA Helicase (HC)DNALAMP, RPA, RCA, SDAMDX241Order a SampleAvailable in 20 ?L (1 µg) or 200 ?L (10 µg) aliquotsGlycerol-free, high concentration enzyme used to unwind double-stranded DNA with the help of an accessory protein, allowing you to deliver reliable results with the added capability for lyophilization. MutLYesYesRequires excipientsYesYes50 µg/mLYes
Lyo-Ready Direct RNA NASBA UrineUrine, RNANASBAMDX223Order a SampleAvailable in 400 mL (50 Rxns) or 2 mL (250 Rxns) aliquotsSingle pot, one-step Nucleic Acid Sequence-Based Amplification (NASBA) for reliable isothermal amplification of RNA transcripts from crude or purified urine samples, ideal for POC testingYesYesLyo-ReadyYesYes2.5xYes
Lyo-Ready Direct RNA NASBA StoolStool, RNANASBAMDX222Order a SampleAvailable in 400 mL (50 Rxns) or 2 mL (250 Rxns) aliquotsSingle pot, one-step Nucleic Acid Sequence-Based Amplification (NASBA) for reliable isothermal amplification of RNA transcripts from crude or purified stool samples, ideal for POC testingYesYesLyo-ReadyYesYes2.5xYes
Lyo-Ready Direct RNA NASBA SalivaSaliva, Sputum, RNANASBAMDX221Order a SampleAvailable in 400 mL (50 Rxns) or 2 mL (250 Rxns) aliquotsSingle pot, one-step Nucleic Acid Sequence-Based Amplification (NASBA) for reliable isothermal amplification of RNA transcripts from crude or purified saliva samples, ideal for POC testingYesYesLyo-ReadyYesYes2.5xYes

Not seeing what you’re looking for? Inquire about a new product

Superior Reproducibility, Sensitivity and Specificity

An ideal lyophilization formulation, for example, should stabilize an enzyme in a freeze-dried format and allow very fast rehydration and reactivation of the enzyme preparations without impacting its performance post rehydration. An ideal formulation should stabilize an enzyme in a freeze-dried or air-dried format and allow fast rehydration and reactivation of the enzyme preparations without impacting its performance post rehydration.

Meridian offers general and sample specific master mixes and glycerol-free enzymes and buffers for the preparation of both lyophilization and air-drying of your assays.

Advanced Enzyme Solutions for Molecular Biology Applications

How to Air-Dry an Assay

See how easy it is to Air-Dry an assay.

Click the play button on the left.

Why We Are Second To None

Meridian offers diagnostic manufacturers the complete solution with over 3,000 antigens and antibodies covering more than 500 diseases and an extensive range of specialty qPCR/RT-qPCR master mixes and molecular enzymes all manufactured under ISO13485 regulations.

Large Sample Size

Lot Reservation

ISO13485

World-Class Customer Service

Catalogs & Brochures

Master Mixes for Molecular Ambient-Temperature Stable Assays

Master Mixes for Molecular Ambient-Temperature Stable Assays

Air-Dryable Mixes

Air-Dryable Mixes

FAQs: Important Principles for Air-Drying Molecular Assays

Can I use the Lyo-Ready mix for air-drying?

No, air-drying requires specific stabilizers, excipients, and preservatives which are different from those required for lyophilization.

Yes, we recommend optimizing the oven temperature and drying time for each new assay formulation (mix including primers and probes), vessel used and lot size. High drying temperatures may affect the integrity of the mix and its components, including enzymes.

Ideally, 70% moisture should be removed from Air-Dryable™ 1-step RT-qPCR Mix (MDX095) and 95% from the Air-Dryable™ Mix (MDX082). However, the optimal moisture loss requires optimization for each assay. Retaining too much moisture may impact the shelf-life of the assay and over-drying may make the mixture difficult to rehydrate and cause a loss of performance. Moisture loss can be calculated by comparing the weight of the initial wet mix in the vessel to the dry mix (refer to the basic workflow for further information). Please note that the air-dried material must be packaged immediately after the drying cycle.

The air-dried mix rehydrates in seconds after the addition of the sample. We do recommend, if possible, to gently shake/mix the vessels in order to resuspend the reaction mix before running the reaction, or alternatively mix the solution when adding the patient sample.

If a mix becomes over-dried, the integrity of the enzymes will be compromised. Conceptually, the ideal “dryness” of a mix will be the highest percentage of moisture loss achieved without losing assay performance. If the Ct value of your dry mix is lower to the comparable wet mix, then the mix has been over-dried and further optimization is required.

We did not observe any effect of the fluorophore type (Cy5, FAM, JOE or ROX) on the performance of the mix after air-drying.

We did not observe any contamination during air-drying however we do recommend good laboratory cleaning practices to minimize possible environmental contamination. Examples include surface cleaning or allocating separate locations for the oven drying, qPCR reaction setup, and analysis. In addition, we recommend maintaining the oven following the cleaning instructions provided by the manufacturer.

We did not observe any cross-contamination from fan-forced oven drying. Given the mix resides at the bottom of the vessel, it is very unlikely that cross-contamination can occur between the wells. In addition, in accordance with good manufacturing practices, we would discourage oven drying two different types of assay in the same drying cycle.

Other vessels can be used such as plates, vials or various microchips, but the drying conditions for each vessel/assay would need to be optimized. Once the ideal conditions and parameters are established, they would need to be verified during validation and scale up.

We recommend using a precision drying oven (temperature uniformity of +/- 1.5°C) with convection, fan-forced or vacuum capabilities. In our testing, we used a Memmert UF260Plus oven with fan and air flap settings at 100% and 20% respectively. Please note that different ovens will have different specifications and adjustable parameters that will need to be optimized based your assay, reaction volume, vessel type, batch size, relative humidity, and altitude.

If the first attempt is not successful and does not provide the correct moisture loss value, we do not recommend putting the tubes back in the oven for additional drying or adding water. We recommend re-starting the experiment in order to control all of the variables so that they are reproducible. In addition, opening the door during the drying process is also not recommended unless it is done in a controllable manner and will be part of the process moving forward.

Unlike the effects with lyophilization, there is no impact of the environment to the moisture loss with air-drying.

We recommend that different drying cycles are performed to test the effect of altering any assay variable such as vessel type, reaction volume, primer/probes, and lot size. This will ensure that the conditions and outcomes are reproducible.

No, the balance does not have to be next to the oven, just close the vessel once it is out of the oven and go to the balance (even if in a different room) for measurement.

Get In Touch With A Specialist

Have questions about a product? Want to learn more about Meridian’s molecular or immunoassay reagent portfolio? We want to hear from you!

By submitting your information in this form, you agree that your personal information may be stored and processed in any country where we have facilities or service providers, and by using our “Contact Us” page you agree to the transfer of information to countries outside of your country of residence, including to the United States, which may provide for different data protection rules than in your country. The information you submit will be governed by our Privacy Statement.